Kohler 4EFOZ Operation Manual page 25

Marine generator sets
Hide thumbs Also See for 4EFOZ:
Table of Contents

Advertisement

Service Schedule—23/27EFOZ, 28/32EOZ Models, continued
Perform Service at Intervals
Indicated (X)
INTAKE/EXHAUST SYSTEM
Inspect the exhaust system components *[
Check the exhaust gas condition. If the exhaust is
blue or black, contact your local distributor/dealer
Replace the intake silencer *
Clean the exhaust/water mixing elbow *[
Check the breather pipe for obstructions *[
Inspect the complete exhaust system
ELECTRICAL SYSTEM
Keep the battery charged and in good condition
Adjust the alternator driving belt tension *
Check and tighten the electrical connections *
Clean the battery cables [
ENGINE AND MOUNTING
Check for water, fuel, coolant, and oil leakage *[
Retighten all major nuts and bolts *
Check the mounting bolts/vibromounts and tighten if
necessary *
Adjust the intake/exhaust valve clearance *
Check the compartment condition (fuel, oil, or water
leaks)
REMOTE CONTROL SYSTEM
Check the remote control operation
GENERATOR
Test run the generator set
Blow dust out of the generator *[
*
Requires removal of the sound shield door, if installed
[
Consult your local distributor/dealer for service
]
Read the WARNING found at the beginning of the manual regarding moving parts
w
Consult the battery manufacturer's instructions
k
Have performed by the your local distributor/dealer
TP-6068 10/02
Reference
Section
3.7
3.7
3.6
3.7
k
2.2
w
3.10
3.9.2
]
[
2.6.3
2.5
3.1
Every
Every
50 Hrs.
200 Hrs.
Before
or 1
Month
Months
Starting
X
X
During
operation
X
X
(Break-in
period)
X
X
X
X
X
X
X
(Break-in
period)
X
(Weekly)
Section 3 Scheduled Maintenance
Every
Every
400 Hrs.
1000 Hrs.
or 3
or 6
or Yearly
Months
X
X
X
X
X
X
X
X
X
X
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents