PRE-INSTALLATION PREPARATION
FRAMING
1. Frame appliance enclosure as illustrated in
Figures 7 and 8.
Note: If a wall covering is used to line the
enclosure, then all measurements must be
from the surface of the covering.
2. Place the appliance into the framing and
secure it.
Note: If appliance is to be raised above floor
level, a platform must be built to support the
appliance.
3. Install the supply line to the appliance using
a 1/2" NPT black iron gas line terminating 2
/
" above the bottom of the appliance. The
5
16
gas line must be installed through the lower
left side access point or alternate access
hole in the bottom of the appliance (see
Figure 16, page 13).
4. Repack insulation around the gas line to
cover any remaining openings in the conduit
sleeve. Prepare the incoming gas line with
teflon tape or pipe joint compound and hook-
up incoming gas line to the flexible gas line.
Note: If 1/2" NPT black iron pipe does not
mate with fitting at the end of flexible gas
line, remove fitting and replace with a 37°
flare 3/4"-12, 1/2" NPT (female) fitting.
WARNING: When finishing
appliance, do not overlap com-
bustible material onto the black
front face. Brick, tile or other
noncombustible materials may
be applied to the face provided
that any gap is between the mate-
rial used and the face is caulked
with a noncombustible caulking.
B
BRT4036TMN, 4336TMN,
4536TMN, 4036TMP,
4336TMP, 4536TMP
A
40
/
" (102 cm)
3
8
B
21
/
" (54.3 cm)
3
8
C 41
/
" (104.8 cm)
1
4
Figure 7 - Rough Opening for Installing
8
C
BRT4042TMN, 4342TMN,
4542TMN, 4042TMP,
4342TMP, 4542TMP
44
/
" (112 cm)
3
8
23
/
" (58.7 cm)
1
8
48
/
" (122.6 cm)
1
4
in Wall
www.SuperiorFireplaces.US.com
Continued
These Dimensions Allow for a 3/4" Clearance
at Sides and Back of Fireplace. However, 0"
Clearance is Permitted.
C
BRT4036TMN, 4336TMN,
4536TMN, 4036TMP,
4336TMP, 4536TMP
A
24
/
1
B
73
/
7
8
C 52
/
3
16
D
17
/
1
Figure 8 - Corner Installation Guidelines
INSTALLING TRANSITION PIPE AND
STARTER COLLAR
The transition pipe and starter collar shown
in Figure 9 are supplied with the fireplace,
unattached and ready for installation. Remove
starter collar and set aside. Slide transition pipe
over vent collar and attach with a minimum
of three screws. Replace starter collar over
transition pipe and attach using four screws
located on leg stands (five used on model
M42). To install B-vent piping, slide the first
piece of B-vent over transition pipe and attach
with either a minimum of two screws or other
means approved by the vent manufacturer.
A
Figure 9 - Installing Transition Pipe and
D
B
3/4" Clearance Not Required
at Nailing Flanges
BRT4042TMN, 4342TMN,
4542TMN, 4042TMP,
4342TMP, 4542TMP
" (62.2 cm)
27
2
" (187.6 cm)
83
" (132.6 cm)
59
5
" (43.8 cm)
19
4
B-Vent Piping
Starter Collar
Transition Pipe
Vent Collar
Starter Collar
A
/
" (70 cm)
9
16
/
" (213 cm)
7
8
/
" (150.6 cm)
16
/
" (49.5 cm)
1
2
126736-01B