Maintenance
4.2
ERROR CODES
When calling Worcester, Bosch Group, you may be asked for the error code. This Table is for you to help identify
the possible cause of the fault.
▶ Do not try to rectify any of the faults listed below by yourself.
▶ Contact British Gas or a competent, qualified engineer (Gas Safe registered personnel).
Error code
Description
b1
Code plug not detected.
C6
Fan speed too low.
E9
Safety temp. limiter in CH flow has tripped.
EA
Flame not detected.
If it safe to do so, check for:
•
gas is on in the house
•
frozen condensate pipe
•
blocked flue outlet
F0
Internal error.
F7
Flame detected even though boiler switched off.
FA
Flame detected after gas shut off.
Fd
Reset button pressed by mistake.
Table 5
Error codes
14