The arrows in the picture indicate the current path.
In case of fault when the appliance is switched on for the first time or in case of a power failure, one of the two
conditions described below occurs:
1. If the internal temperature is higher or the same as the sensor cut-in temperature (CUT-IN),
when the power is restored, the electronic board activates the compressor and the fan till the set
temperature is reached and after 5 hours the electronic board activates the defrosting procedure
(after the compressor cut-out).
2. If the internal temperature is lower than the sensor cut-in temperature (CUT-IN), when the power
is restored, the compressor functions in thermostatic conditions and after 5 hours the electronic
board activates the defrosting procedure (after the compressor cut-out).
The electronic board activates, in any case, the defrosting procedure 5 hours after the first switching on and after
a power failure.
PARTIAL NO FROST REFRIGERATORS with ERF2021 electronic
7.2. Normal with first switching on or power failure
25/41