Rinnai REU‐VC2528FFUD‐US Installation And Operation Manual page 8

Direct vent tankless water heater
Table of Contents

Advertisement

Addi onal clearances ‐ RL75i, RL94i 
Check on whether local codes supersede these clearances. 
Avoid termina on loca ons near a dryer vent. 
Avoid termina on loca ons near commercial 
cooking exhaust. 
You must install a vent termina on at least 12 
inches from the ground. 
Important considera ons for loca ng vent 
termina on under a soffit (ven lated or unven lated 
or eave vent; or to a deck or porch) 
Do not install vent termina on under a soffit vent 
such that exhaust can enter the soffit vent 
Install vent termina on such that exhaust and 
rising moisture will not collect under 
eaves.  Discolora on to the exterior of the 
building could occur if installed too close. 
Do not install the vent termina on too close 
under the soffit where it could present 
recircula on of exhaust gases back into the 
combus on air intake part of the termina on. 
(0.30 m ) to 
an inside 
corner 
 
36"
12"
V
V
12"
(0.30 m) between  
terminals at same 
level 
INSIDE
CORNER
(1.52 m) 
between  
terminals at 
different levels 
 
V
VC Series Manual 
60"
V
V
(1.52 m) ver cally 
60"
between terminals 
V
(0.61 m) to wall or parapet 
24"
V
12"
(0.30 m) between  
terminals at same 
V
level 
V