WARNING
Tes ng the pressure relief valve should only be 
performed by a licensed professional.  Scalding hot 
water may be released under pressure. 
Pressure Relief Valve: 
Operate the valve manually once a year.  In doing so, 
it will be necessary to take precau ons with regard to 
the discharge of poten ally scalding hot water under 
pressure.  Ensure discharge has a place to flow.  
Contact with your body or other property may cause 
damage or harm. 
Visual Inspec on of Flame 
Verify proper opera on a er servicing.   
The burner must flame evenly over the en re surface 
when opera ng correctly.  The flame must burn with a 
clear, blue, stable flame.  See the parts breakdown  of 
the burner for the loca on of the view ports.   
The flame pa ern should be as shown in the figures 
below. 
40 
Freeze Protec on 
Make sure that in case of freezing weather that the 
water heater and its water lines are adequately 
protected to prevent freezing.  Damage due to 
freezing is not covered by the warranty.  Refer to the 
sec on on Freeze Protec on.
Winterizing 
These recommenda ons are intended to suggest 
prac ces which are effec ve for winterizing the water 
heater.  They should be used as a guide only.  No 
liability is assumed for any issues resul ng from the 
use of this informa on. 
GAS 
Shut off the gas to the water heater.  It is generally 
preferable to shut off the gas service to the en re 
loca on if gas is not going to be used. 
WATER   
Shut off the cold water supply to the water heater.  It 
is generally preferable to shut off the water to the 
en re loca on if water is not going to be used. 
Drain the water heater by opening the drain valves on 
the cold water line and hot water line. 
Open several hot water taps and remove the filter 
assembly at the water inlet in order to allow room for 
expansion in case there is water in the lines that 
freeze. 
ELECTRIC 
Disconnect the power supply by either unplugging the 
electrical cord or by turning off the circuit breaker to 
the water heater to prevent poten al damage from 
irregular power surges or interrup ons. 
VENT TERMINATION 
Place a cover over the vent termina on (intake and 
exhaust) if it can be safely accessed.  The cover should 
be easy to apply and remove.  This will prevent 
debris, leaves, and small animals from entering the 
ven ng and water heater which could cause air flow 
issues upon return to service. 