Models With Dispenser and Fresh Food Compartment Ice Maker
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING
Type A with Run/Start Capacitor
Operating Time
Freezer Temperature
Refrigerator Temperature
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle)
Amps (running)
Base Voltage
Cabinet Size
26' & 28' SD, 23' CD
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
Watts
3.1
Electrical
Thermostat
Heater Voltage
Wire Number
1
2
3
4
65°F (18°C) Ambient
74 to 84%
-5° to 2° F (-20° to -17° C)
34° to 39° F (1° to 4° C)
5 to 12 psig (34 to 83 kPa)
-2 to 2 psig ( -14 to 14 kPa)
85 to 95 psig (586 to 655 kPa)
45 to 55
.6 to 1.1
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat
Cut-in
25° F (-4° C)
47° F (8° C)
CONDENSER FAN MOTOR
RPM
1100 CW Opposite Shaft
ICE MAKER SPECIFICATIONS
115 vac (127 vac max)
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)
85 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Color
Green/Yellow
Yellow
Black
Light Blue
1-9
Basic Information
90°F (32°C) Ambient
-1° to 3° F (-18° to -16° C)
34° to 39° F (1° to 4° C)
-2 to 2 psig (-14 to 14 kPa)
120 to 135 psig (827 to 931 kPa)
Cut-out
Watts
500
0.03 Running
100%
N/A
60 to 70
.7 to .9
Heater
Ohms
31
Amps
Connects to:
Ground
Water Valve
Line
Neutral