Settings Sheet - Fujitsu 112 Installation And Operating Manual

Heat pump air/water split single service 3 phase
Hide thumbs Also See for 112:
Table of Contents

Advertisement

Heat pump split single service 3 phase
7 3

Settings sheet

Setting
Description
Preliminary settings
20
language
1
hour / minutes
2
day / month
3
year
5700
installation config .
Heating circuit No 1
if 2 circuits = the least warm one (e g : floor)
710
comfort setpoint
712
reduced setpoint
720
heating curve slope
741
flow temp setpoint max
750
room influence
790 / 791
optimis . at switch-on / off
834
servomotor travel time
850 / 851
floor drying
501 to 516
time programs
642 to 648
holiday programs
Heating circuit No 2 (with 2
= the warmest one (e g : radiators)
1010
comfort setpoint
1012
reduced setpoint
1020
heating curve slope
1041
flow temp setpoint max
1050
room influence
1090 / 1091
optimis . at switch-on / off
1134
servomotor travel time
1150 / 1151
floor drying
521 to 536
time programs
652 to 658
holiday programs
Domestic Hot Water (if DHW kit)
1610
nominal DHW temp . setpoint
1612
reduced DWH temp . setpoint
1620
DHW release
1640 to 1647 legionella cycle
1660
release DHW circulation
5020
flow temp . increase
5024
DHW switch-on differ .
5030
charging time limitation
5060
heater operation mode
5061
heater release
5870
tank present (if DHW kit)
561 to 576
time programs
Installation and operating manual "1364 - EN"
Set to.
Menus
operator section
time & date
time & date
time & date
configuration
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 program.
HC1 hol pgm.
circuit option)
nd
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 program.
HC1 hol pgm.
DHW
DHW
DHW
DHW
DHW
DHW tank
DHW tank
DHW tank
fill .
DHW tank
DHW tank
configuration
prog.4 DHW
Setting
Description
Boiler backup
3700
OT .switch-on authoris .
3705
swith-off delay
Miscellaneous
6046
input H2 function
6100
OT sensor correction
6120
frost protection on/off
6205
reset settings
6220
software version
6711
reset heat pump
7070 to 7183 maintenance
7700 to 7916 input / output testing
8402 to 8457 generator diagnosis
8700 to 9055 consumer diagnosis
Cooling
5711
cooling unit
901 to 969
cooling settings
Faults (if a fault occurs, press"Info" key)
No . 10
outdoor sensor
No . 33
flow temp . sensor
No . 44
return temp . sensor
No . 50
DHW temp . sensor
No . 60
room sensor 1
No . 65
room sensor 2
No . 105
maintenance message
No . 121
HC1 flow T not reached
No . 122
HC2 flow T not reached
No . 127
leg . prot . T not reached
No . 369
external fault (EX6)
No . 370
outdoor unit connect error
6740 to 6746 alarm timeout
6800 to 6818 last 10 alarms history
6711
reset heat pump
Heat pump
2844
switch-off temp max
2884
OT auth . to start elec . aux .
2920
Pk day clear (EX4) rel / lock
Swimming pool (with "swimming pool" kit option)
2056
generator setpoint
Outdoor unit faults (see
page
Set to.
Menus
addit. gen.
addit. gen.
9
configuration
configuration
configuration
configuration
configuration
error
maintenance
I/O testing
gen. diagn.
cons. diagn.
2 pipes
configuration
cooling circuit 1
error
error
error
heat pump
heat pump
heat pump
Sw pool
54)
- 57 -