Panasonic CU-2E15LBE Service Manual page 62

Outdoor unit
Table of Contents

Advertisement

Diagnosis
Abnormality
display
or
LED 6 LED 5 LED 4 LED 3 LED 2 LED 1
protection
control
F97
Compressor
overheating
protection
F98
Total running
current
protection
F99
Outdoor direct
current (DC)
peak detection
LED 1 illuminate is indicated that outdoor unit is operating normally. If the LED 1 is switched off or flashing, check the power supply
and self-diagnosis indication.
------ Illuminate
------ Flashing
Blank ------ OFF
Abnormality
Protection
judgement
operation
3 times
happen within
30 minutes
3 times
happen within
20 minutes
Continuous
happen for 7
times
62
Problem
Check location
Compressor
• Insufficient
overheat
refrigerant
Total current
• Check
protection
refrigeration
system
• Power source or
compressor lock
Power transistor
• Power transistor
module current
module faulty or
protection
compressor lock