Panasonic CU-2E15LBE Service Manual page 59

Outdoor unit
Table of Contents

Advertisement

Abnormality or protection control
Diagnosis
display
F93
Outdoor compressor abnormal
revolution
F95
Cooling high pressure protection
F96
IPM (power transistor) overheating
protection
F97
Outdoor compressor overheating
protection
F98
Total running current protection
F99
Outdoor direct current (DC) peak
detection
Note:
" " - Frequency measured and fan speed fixed.
Abnormality
judgement
4 times occurrences
within 20 minutes
4 times occurrences
within 20 minutes
4 times occurrences
within 10 minutes
3 times occurrences
within 20 minutes
7 times occurrences
59
Emergency
Primary location to verify
operation
• Compressor
• Outdoor refrigerant cycle
• Express refrigerant
• Improper heat radiation
• Outdoor PCB
• Insufficient refrigerant
• Compressor
• Excess refrigerant
• Improper heat radiation
• Outdoor PCB
• Compressor