Cleaning/Inspecting The Strainer; Transport; Fault Finding; After Use Storage - Bosch Aquatak 1200 Plus Operating Instructions Manual

Bosch aquatak pressure washers operating instructions
Hide thumbs Also See for Aquatak 1200 Plus:
Table of Contents

Advertisement

F016 L70 898.book Seite 5 Mittwoch, 25. Juli 2012 11:46 11

Cleaning/inspecting the strainer

Expose the strainer 14 in the machine water inlet
L
connection by removing the inlet connector 7.
Rinse and replace. If damaged replace.
Never use the pressure washer without the strainer
or a damaged strainer.

Transport

To move the machine use the top handle and roll the
machine on the wheels.
To transport the unit up or down steps or over obsta-
cles, it must be lifted by the top handle.

Fault Finding

The following table gives checks and actions that you can perform if your machine does not operate correctly.
If these do not identify/remedy the problem, contact your service agent.
Warning: Switch off and remove plug from mains before investigating fault.
Symptom
Motor refuses to start
Motor stops
Fuses blow
Excessive working pres-
sure
Pressure pulsating
17 • F 016 L70 898 • 12.07
Possible Cause
Plug not connected
Mains socket faulty
Fuse faulty/blown
Extension cable damaged
Motor protector has activated
Frozen
Fuse faulty/blown
Wrong mains voltage
Motor protector has activated
Fuses faulty/blown
Nozzle partly blocked
Air in the inlet water supply hose/pump
Inadequate water supply
Water strainer blocked
Water supply hoses squeezed
High pressure hose too long
English - 5
AQUATAK 1250
If the unit is to be stored or transported horizontally
the detergent tank should be drained first.

After use storage

Clean the exterior of the machine thoroughly using a
soft brush or cloth. Do not use water, solvents or pol-
ishes. Remove all debris, especially from the venti-
lation slots.
Frost will damage a pressure washer that has not
been completely emptied of water. The machine
should be stored in a frost free room.
Do not place other objects on top of the machine.
Remedy
Connect plug
Use another socket
Replace fuse
Try without extension cable
Allow to cool for 5 minutes
Wait for pump/water supply hose/ac-
cessory to thaw
Replace fuse
Check that mains voltage corresponds
to specifications on the model tag
Allow to cool for 5 minutes
Change to a mains supply higher than
the pressure washer amp consumption
Clean nozzle
Allow pressure washer to run with
open spray handle and nozzle at low
pressure until regular working pres-
sure is obtained.
Check that the water supply corre-
sponds to specifications. The minimum
specification for the water supply hose
is 1/2" or 13 mm diameter.
Clean water strainer
Straighten out kinked water supply
hoses
Dismount high pressure extension
hose. Retry (extension hose max. 7 m)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquatak 1250

Table of Contents