Installing/Replacing The Power Supply Unit - Panasonic KX-TDE100 Installation Manual

Pure ip-pbx
Hide thumbs Also See for KX-TDE100:
Table of Contents

Advertisement

3.2.4 Installing/Replacing the Power Supply Unit

3.2.4 Installing/Replacing the Power Supply Unit
Function
PSU Type
PSU-S
(for KX-TDE100)
PSU-M
(for KX-TDE100/
KX-TDE200)
PSU-L
(for KX-TDE200)
Battery Switch
Battery Connector
Power Switch
Earth Terminal
AC Inlet
Accessories and User-supplied Items
Accessories (included): Screws ´ 4
User-supplied (not included): Earthing wire, Back-up Battery Cable (KX-A228 for PSU-S and PSU-M, or
KX-A229 for PSU-L)
Note
For details about frame earth connection, refer to "3.2.5 Frame Earth Connection".
For details about backup batteries connection, refer to "3.2.6 Backup Battery Connection".
Safety Instructions
Each PSU complies with Safety Class 1 of IEC60950, EN60950, UL60950, CAN/CSA-C22.2 No.60950, and
AS/NZS60950; therefore a protective earth connection exists between the mains outlet ground and the PSU
case. To ensure the PBX chassis is safely grounded, it is essential that the PSU case be securely fastened to
the PBX chassis with the 4 screws provided with each PSU.
When installing or replacing a PSU, basic safety precautions should always be followed to reduce the risk of
fire, electric shock and injury to persons, including the following:
1.
Never install or replace a PSU during a lightning storm.
2.
Never install or replace a PSU in wet locations.
56
Installation Manual
Lower/Upper Input Voltage Range
Lower: 100 V AC to 130 V AC
Upper: 200 V AC to 240 V AC
Lower: 100 V AC to 130 V AC
Upper: 200 V AC to 240 V AC
Lower: 100 V AC to 130 V AC
Upper: 200 V AC to 240 V AC
PSU-S
Current
1.4 A
0.8 A
2.5 A
1.4 A
5.1 A
2.55 A
PSU-M/PSU-L
Battery Switch
Battery Connector
Earth Terminal
Power Switch
AC Inlet
Input Frequency
50 Hz or 60 Hz

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pure ip-pbxKx-tde200Tde100Tde200

Table of Contents