WATeR ConneCTion
Blodgett BCM/BLCM ovens have two water connections.
Both are located at the back of the unit.
BCM/BLCM-61, 62,101, 102 and 202 models
1 connection for raw water for the condensation jet.
1 connection for steam generation and the Combi
Wash jet in the oven chamber. Must meet the re-
quirements applying to water supplied to household
appliances.
Quench
Figure 3
BLCM-23, 6 and 10 Mini Combi models
1 water connection. Must meet the requirements ap-
plying to water supplied to household appliances.
Figure 4
WARninG!!
if the water temperature exceeds 70°F (21°C),
problems with regard to Combi optima cali-
bration and cooling of the oven may occur.
The water connection must be carried out by
an authorized plumber in accordance with
existing local codes.
Clogged up water filters and dirt in the sole-
noid valves are not covered by the warranty.
Steam
Water
connection
9
Installation

Plumbing Connections

To facilitate cleaning and servicing, the oven should be
connected with an approved flexible 3/4" hose. Perma-
nent installations should be fitted with a stop-tap and a
non-return valve.
Before connecting the oven to water, flush the tubes
thoroughly. Connect the oven.
DRAin ConneCTion
Blodgett ovens are equipped with a drain system that re-
moves surplus water from the oven chamber. This may
be condensed water from the products, or it may occur
when the oven chamber is cooled down with cold water,
or when the oven chamber is cleaned.
WARninG!!
Connection must be carried out by an autho-
rised plumber, to an open or closed drain.
The drain must never end directly beneath the
oven.
The drain must be of stainless steel or an equally tem-
perature-resistant material, have a diameter of at least 2"
(49 mm) and a fall of at least 3° or 5%.