Dimplex QM070 Installation Instructions Manual

Dimplex QM070 Installation Instructions Manual

Quantum heater

Advertisement

A world of expertise
11115-5
Rev. 123/125
- 1 -

Installation Instructions

IMPORTANT
These instructions should be read carefully and retained for
future use.
Note also the information presented on the appliance.
Quantum Heater
Models:
QM070
Boost
Output
230/240V~:
567/630W
Storage
Element
Rating
230/240V~:
1435/1560W
Rated
Charge
Period:
7.7 - 7 Hours
Energy Cells:
18
Installed
Weight:
91kg
kWh:
10.9kWh
QM100
QM125
792/880W
1017/1130W
2042/2220W
2540/2760W
24
30
115kg
142kg
15.5kWh
19.3kWh
QM150
1242/1380W
3024/3300W
36
165kg
23.1kWh

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex QM070

  • Page 1: Installation Instructions

    Installation Instructions A world of expertise IMPORTANT These instructions should be read carefully and retained for future use. Note also the information presented on the appliance. Quantum Heater Models: QM070 QM100 QM125 QM150 Boost Output 230/240V~: 567/630W 792/880W 1017/1130W 1242/1380W...
  • Page 2 IMPORTANT WARNING - THE SURFACE OF THIS HEATER CAN BE HOT. WARNING - THIS APPLIANCE MUST BE EARTHED. • The installation must be carried out by a suitably qualifi ed individual in accordance with the latest IEE Regulations for IMPORTANT electrical equipment.
  • Page 3 fi tted around the heater, as is normal with heating appliances in similar circumstances. A range of guards specially designed for Dimplex heaters is available. If you require further information on these guards, please see contact details on back page of the Operating Instructions.
  • Page 4 Remove the feet and the fi xing kit. Fig. 1 2. Secure the feet to the heater. For models QM070 and QM100 two locations are possible indicated by X and Y markings visible on the base of the heater.
  • Page 5 3. Ensure the heater is stable before removing the screws which hold the grille panel in position. Set the grille to one side. Fig. 3 4. Remove the two screws located towards to bottom of either end of the heater, which retain the heater sides.
  • Page 6: Installing The Heater

    Installing the Heater The heater must be securely fi xed to a wall. Screws with suitable wall fi xings for solid walls are provided. If other wall types are encountered it is the installer who must choose the most suitable fi xing. SUGGESTED FIXINGS SOLID BRICK/BLOCK: No.
  • Page 7 Fig. 6 7. Six fi xing positions must be selected for each QM070 Fig. 7 model. Mark the positions for the fi xing holes. Remove the bracket from the wall, drill the holes and fi...
  • Page 8: Electrical Connections

    Warning: Before obtaining access Electrical Connections to terminals, all supply circuits 8. The heater leaves the factory confi gured must be disconnected. to operate with two mains supplies, a 24 hour supply and an off peak switched supply. Two Mains Supplies Storage / Fan circuit Ensure the brown wire is connected to the terminal marked L.
  • Page 9 9. The mains cable entry bushes and terminal blocks will be visible on the right hand side of the unit. Insert the mains cables through the cable gland at the bottom of the heater in readiness for connection. IMPORTANT - Only heat resistant ordinary polyvinyl chloride sheathed fl...
  • Page 10 Building the Heater Core 10. Remove the inner front and insulation to gain access to the core of the heater. Lay the inner front carefully to one side to ensure it is not damaged. Fig. 10 Fig. 10 11. Remove the internal packaging. Fig.
  • Page 11 Bricks The bricks are supplied separately to the heater in packs of three. The reference number is 047243. 12. The bricks have several grooves on one surface for locating around the elements. The two slots through the centre of the brick create the air passages within the core.
  • Page 12 14. The third row of brick is positioned in a manner similar to the fi rst row. Again be careful not to damage or dislodge the element. Fig. 14 15. Fit the fourth row of brick above the third row in the upside position.
  • Page 13 17. Close the core by refi tting the inner front panel complete with insulation. Ensure the bottom edge is located inside the chassis and that the screws are tightly secured down each edge. Fig. 17 IMPORTANT Double check all mains connections are secure and excess cable is restrained and not in contact with any of the heater casing.
  • Page 14 ‘Slave Mode’ and press Selector Dial. Select ‘Enable’. Slave Mode Disable Enable Information For cleaning, heater guards or other sales service and Dimplex contact details please refer to the Operating Instructions. - 14 -...
  • Page 15 - 15 -...
  • Page 16 Circuit Diagram SERIES D - 16 -...

This manual is also suitable for:

Qm100Qm150Qm125

Table of Contents