Carrier ROOM AIR CONDITIONER Installation Manual page 8

Inverter one-two/one-three/one-four/one-five split-type
Hide thumbs Also See for ROOM AIR CONDITIONER:
Table of Contents

Advertisement

2. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.
Connective pipe installation
1. For the left-hand and right-hand piping,
remove the pipe cover from the side
panel.
2. For the rear-right-hand and rear-left-hand
piping, install the piping as shown in Fig.10.
3. Fix the end of the connective pipe. (Refer
to Tightening Connection in REFRIGERANT
PIPING CONNECTION)
4. Piping and wrapping
Bundle the tubing, connecting cable, and drain
hose with tape securely, evenly as shown in
Fig.11.
Because the condensed water from rear of the
indoor unit is gathered in ponding box and is
piped out of room. Do not put anything else in
the box.
CAUTION
Connect the indoor unit first, then the
outdoor unit.
Do not allow the piping to let out from
the back of the indoor unit.
Be careful not to let the drain hose slack.
Heat insulated both of the auxiliary piping.
Be sure that the drain hose is located at
the lowest side of the bundle. Locating
at the upper side can cause drain pan
to overflow inside the unit.
Never intercross nor intertwist the power
wire with any other wiring.
Run the drain hose sloped downward to
drain out the condensed water smoothly.
INSTALLATION INSTRUCTIONS
Right-hand piping
Left-hand piping
Fig.9
Indoor unit
Connective
cable
Drain hose
7
Fig.8
Rear-right piping
Rear-left piping
Fig.10
Ponding box
Pipe room
.
Connective
. .
.
.
.
.
.
.
.
. .
pipe
. .
.
.
.
.
. .
.
.
. .
.
. .
. .
. . .
Wrapping belt
Fig.11