For assistance with your machine, visit our website at www.deltaportercable.com for a list of service centers or call the
DELTA Machinery help line at 1-800-223-7278 (In Canada call 1-800-463-3582).
To reduce the risk of injury, turn unit off and disconnect it from power source before installing and
removing accessories, before adjusting or when making repairs. An accidental start-up can cause injury.
KEEP MACHINE CLEAN
Periodically blow out all air passages with dry compressed air. All plastic parts should be cleaned with a soft damp cloth.
NEVER use solvents to clean plastic parts. They could possibly dissolve or otherwise damage the material.
Wear certified safety equipment for eye, hearing and respiratory protection while using compressed air
FAILURE TO START
Should your machine fail to start, check to make sure the prongs on the cord plug are making good contact in the outlet.
Also, check for blown fuses or open circuit breakers in the line.
LUBRICATION & RUST PROTECTION
Apply household floor paste wax to the machine table, extension table or other work surface weekly. Or use a
commercially available protective product designed for this purpose. Follow the manufacturer's instructions for use and
safety.
To clean cast iron tables of rust, you will need the following materials: a medium sized scouring pad, a can of spray
lubricant and a can of degreaser. Apply the spray lubricant and polish the table surface with the scouring pad. Degrease
the table, then apply the protective product as described above.
OVERLOAd PROTECTOR
Your scroll saw is equipped with a 3 amp overload
protection fuse. If your scroll saw becomes overloaded
and stops operating, turn off the scroll saw, check for a
blown fuse by removing the fuse cap (Figure 12). Your
scroll saw uses fuse #3AG Fast Acting, 1-1/4" (31.7 mm)
long x 1/4" (6.3 mm) diameter.
BRUSHES
Inspect carbon brushes regularly by unplugging tool,
removing the brush inspection cap (Figure 12) and
withdrawing the brush assembly. Keep brushes clean
and sliding freely in their guides. Always replace a used
brush in the same orientation in the holder as it was prior
to its removal. If the brush is worn down to 3/8" (10 mm),
it must be replaced. Use only identical DELTA brushes.
New brush assemblies are available at DELTA service
centers. The tool should be allowed to "run in" (run at no
load) for 10 minutes before use to seat new brushes.
TABLE
Keep the table clean and free from oil, grease and pitch.
Treat the table with paste wax to help maintain its smooth
finish.
REPLACEMENT PARTS
Use only identical replacement parts. For a parts list or to order parts, visit our website at www.deltaportercableservicenet.com.
You can also order parts from your nearest factory-owned branch, Authorized Warranty Service Center or by calling End
User Services at (800) 223-7278 to receive personalized support from one of our highly-trained representatives.

TROUBLESHOOTINg

MAINTENANCE

SERVICE

11
BRUSH
INSPECTION
CAPS
FUSE CAP
(INSERT THE TOOL
ANd PRESS TO
RELEASE)
FIg. 12