Specifications; Electrical Data - Lennox HP21 Unit Information

Hp21 series
Table of Contents

Advertisement

Model No.
Face area (sq.ft.)
outside / inside
Tube diameter (in.)
Outdoor Coil
No. of Rows
Fins per inch
Diameter (in.)
No. of Blades
Motor hp
Outdoor Fan
Cfm
Rpm
Watts
Refrigerant−22 (charge furnished)
Liquid line connection (sweat)
Vapor line connection (sweat)
Model No.
Line voltage data − 60hz.
Rated load amps
Compressor
Power factor
Locked rotor amps
Full load amps
Outdoor Coil
Fan Motor
Locked rotor amps
Max fuse or circuit breaker size (amps)
*Minimum circuit ampacity
*Refer to National Electrical Code Manual to determine wire, fuse and disconnect size requirements.
NOTE − Extremes of operating range are plus 10% and minus 5% of line voltage

SPECIFICATIONS

HP21−411
HP21−36−230
HP21−36−233
HP21−413
18.22/
17.53
3/8
2
18
24
3
1/10
3120
820
155
13lbs. 10oz.
3/8
3/4

ELECTRICAL DATA

HP21−413
HP21−411
HP21−36−233
HP21−36−230
208/230/1ph
208/230/3ph
17.6
12.7
.98
.90
90.0
60.0
0.7
0.7
1.2
1.2
40
25
22.7
16.6
Page 2
HP21−511
HP21−48−230
HP21−48−233
HP21−513
21.64/
20.81
3/8
2
18
24
3
1/6
3200
815
200
15lbs. 5oz.
3/8
7/8
HP21−511
HP21−513
HP21−48−230
HP21−48−233
208/230/1ph
208/230/3ph
17.6
12.7
.98
.90
90.0
60.0
1.0
1.0
1.9
1.9
40
25
23.0
16.9
HP21−651
HP21−60−230
HP21−653
HP21−60−233
23.92/
23.01
3/8
2
20
24
4
1/4
4200
815
310
18lbs. 10oz.
3/8
1−1/8
HP21−651
HP21−653
HP21−60−230
HP21−60−233
208/230/1ph
208/230/3ph
30.8
19.9
.92
.90
141.0
91.0
1.7
1.7
2.9
2.9
60
45
40.2
27.0