Tanita BC-420MA Instruction Manual

Tanita BC-420MA Instruction Manual

Body composition analyzer

Advertisement

GB
BODY COMPOSITION ANALYZER
BC-420MA
Instruction manual
REMOTE DISPLAY VERSION
COLUMN MOUNTED VERSION
Please read this Instruction Manual carefully and keep it
handy for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Tanita BC-420MA

  • Page 1 BODY COMPOSITION ANALYZER BC-420MA Instruction manual REMOTE DISPLAY VERSION COLUMN MOUNTED VERSION Please read this Instruction Manual carefully and keep it handy for future reference.
  • Page 2: Table Of Contents

    Table of Contents Before use (cautions for safety) Safety Notes •••••••••••••••••••••••••••••••••••••••••••• Part names / connecting method •••••••••••••••••• Preparation ••••••••••••••••••••••••••••••••••••••••••••• Various settings •••••••••••••••••••••••••••••••••••••• How to use (cautions for safety) Operating Instructions ••••••• When using as a body composition monitor ••• Target body fat ratio ••••••••••••••••••••••••••••••••...
  • Page 4: Product Assembly And Components

    Product Assembly and Components Remote display version Column mounted version Control Box Accessories Accessories Printer cover Instruction manual (This manual) Instruction manual (This manual) Operation guide Assembling guide AC adapter AC adapter AC cord AC cord Control Box Syringe (1 item) Hexagonal wrench (1 item) Hexagon socket head bolts (M5L12) (4 items)
  • Page 5: Preparation

    Preparation Setting of the printer paper roll • Please change the paper roll when red lines appear along the sides of the paper. Control panel • Please pay careful attention to avoid injury from the sharp edge. • Please turn off the machine before clearing Paper jams. Setting of the printer paper roll Press to turn on the power.
  • Page 6 Setting items Print item setting ON / OFF Press Set Up Date and time( page 12) TANITA Logo ( page 22) • The setting item input screen is displayed. Category name ( page 22) Number of sheets to print • 39 – 67 are the setting items related to print out items...
  • Page 7 Various settings Setting methods (continued) Register the date and time Set the number of sheets to print for the body composition monitor (Continued from page 10). (Continued from page 10). Press and then press Press and then press Enter / Next Enter / Next •...
  • Page 8 Various settings Setting methods (continued) Set ON / OFF of the automatic cutting of the printer paper Set ON / OFF of the Fat % Healthy range display (Continued from page 10). (Continued from page 10). Press and then press Press and then press Enter / Next...
  • Page 9 Various settings Setting methods (continued) Select the measurement flow Set the input unit of height (Continued from page 10). (Continued from page 10). Press and then press Press and then press Enter / Next • The “ON or OFF of the one step mode” selection screen is Enter / Next displayed.
  • Page 10 Various settings Setting methods (continued) Set ON / OFF of the target body fat ratio Set the print item preset (Continued from page 10). (Continued from page 10). Press and then press Press and then press Enter / Next Enter / Next •...
  • Page 11 17 years old or younger are for reference. Please consult your doctor before you start a body weight management program. Tanita is not responsible for the target body fat ratio. Please consult your doctor before you start a body weight management program. Tanita is not responsible...
  • Page 12 Set the items to print out (Continued from page 10). Select the number to set with the <In the case of selecting 39> Print item setting ON / OFF TANITA Logo Metabolic age numeric keys ( – Category name Visceral fat rating...
  • Page 13: Operating Instructions

    Operating Instructions when using as a body composition analyzer This explains the procedure when the printer is turned on. Please be aware that the display may be Check that the body different if the number of print outs is set to composition monitor is selected •...
  • Page 14 Operating Instructions when using as a body composition analyzer(continued) Step on the electrodes with bare Press Enter / Next feet. Note Take off your socks and stockings before stepping on. • This screen is not displayed if OFF is set in the “setting with or without an ID”...
  • Page 15 Operating Instructions when using as a body composition analyzer(continued) Input the age. Measurement completion Input it by pressing – The measurement result and the body fat percentage evaluation are displayed. It is automatically printed out. (In the case that other Note than 0 is set in the “Setting the number of sheets to •...
  • Page 16 Operating Instructions when using as a body composition analyzer(continued) In the case of the one step mode Input the ID number. Input it by pressing In the one step mode, after inputting the personal data, the weight and body composition are measured. Note Personal data input Weight measurement...
  • Page 17 Operating Instructions when using as a body composition analyzer(continued) Input the age. Step on the electrodes with bare Input it by pressing – feet. Take off your socks and stockings before stepping on. Note • The age can be input from 5 – 99. •...
  • Page 18: Target Body Fat Ratio

    Input it by pressing – Before you start a body weight management program and set the appropriate personal body fat ratio, please consult your doctor. Tanita is not responsible for setting the Note appropriate target body fat ratio for specific individuals.
  • Page 19 Operating Instructions when using as a scale (continued) Input an ID number. Measurement completion Input it by pressing – The measurement result and the body fat percentage evaluation are displayed. It is automatically printed out. (In the case that other Note than 0 is set in the “Setting the number of sheets to •...
  • Page 20: Various Criteria

    2 diabetes. (-) : Underfat; below the healthy body fat range. Increased risk for health The Tanita Body Composition Monitor will provide you with a visceral fat rating from 1 – 59. problems.
  • Page 21 The basic way of calculating Basal Metabolic Rate BMR is a standard equation using weight and age. Tanita has conducted in-depth research into the relationship of BMR and body composition giving a much more accurate and personalized reading for the user based on the impedance measurement. This method has been medically validated using indirect calorimetry (measuring the breath composition).*...
  • Page 22: Troubleshooting

    Troubleshooting - Please check the following before asking for repair. Symptom Please check Symptom Please check Impedance Run out of print paper measurement error •Print paper is not supplied. e Supply paper. e In the case that the printer is not used, press •Measure with bare feet.
  • Page 23: Connection With A Personal Computer

    Connection with a personal computer - Connection Example BC-420MA conforms to the IEC60601-1 safety standard. If you connect it to a computer, please connect it to one that conforms to IEC60950. Please be sure to use a straight cable when the equipment is connected to an external computer.
  • Page 24 Transmission Data is output immediately after measurement regardless of the status of (2). Output data items the receiving equipment (personal computer, etc.). Therefore the receiving equipment Order of output needs to be ready to accept the data before measuring. Item Header Format Contents...
  • Page 25: Technical Notes

    The Tanita Body Composition Analyzer measures body composition using a constant current source with a high frequency current (50kHz, 90µA). The 8 electrodes are positioned so that electric current is supplied from the electrodes on the tips of the toes of both feet, and voltage is measured on the heel of both feet.
  • Page 26 - Factors giving errors in measurement 1) Temporary increases in body weight (total body water) through overeating and overdrinking 2) Dehydration due to heavy sweating during vigorous exercise 3) Dehydration due to alcohol consumption or the use of diuretics In the BIA method, impedance is measured and the body composition is calculated based on the value. It is known that impedance changes by the amount of the total body water that occupies about 60% of 4) Dehydration due to heavy sweating during saunas, etc.
  • Page 27 First Annual Nutrition Week (American College of Nutrition, American Society for Clinical Nutrition, Currently, the BMR estimation recursion formula developed by Tanita, the manufacturer of body American Society for Parenteral and Enteral Nutrition, North American Association for the Study of composition analyzers, based on their research, works by multiple regressive analysis using this FFM, and Obesity) held in 2002 in San Diego.
  • Page 28: Specifications

    Height 90 - 249.9 cm / 0.1 cm increments Power Consumption 28 W FAT% 3 - 75% / 0.1% increments Tetra polar Bioelectrical Impedance Analysis TANITA LOGO (240x64 dot) Measurement System Logo Measurement Frequency 50 kHz Model Name BC-420MA Measurement Current 90 µA...
  • Page 29 Copyright © 2005 TANITA Corporation. All Rights Reserved.

Table of Contents