9.64 Main PCB
(1) Disconnect the 6 connectors and 6 flat cables from the Main PCB.
Caution:
• After disconnecting flat cable(s), check that each cable is not damaged at its end or
short-circuited.
• When connecting flat cable(s), do not insert them at an angle. After insertion, check
that the cables are not at an angle.
DX solenoid connector
(For the models
with the DX only)
Relay rear (Flat cable)
Relay front (Flat cable)
Assembling Note:
• When assembling the Main PCB, ensure to place the Ferrite Core correctly.
LD harness (Flat cable)
Fig. 5-131
5-103
Wireless PCB harness
(For the model with
the Wireless LAN only)
Polygon motor (Flat cable)
LVPS PCB connector
Main motor (Flat cable)
Ferrite core
Thermistor connector
HVPS PCB (Flat cable)
FAN connector
LT connector
Confidential