Mobile Home Installation; General Procedures; Installation Of External Air Duct - Appalachian Stove & Fabricators Trailmaster 4N1-XL Installation And Operation Procedures

Table of Contents

Advertisement

IV . MOBILE HOME INSTALLATION

1. GENERAL PROCEDURES

Follow the installation instructions for a freestanding
stove, with the following changes:
(A) The structural integrity of the mobile home floor,
wall, and ceiling/roof must be maintained throughout
the installation.
(B) DO NOT install the 4N1-XL stove in a sleeping
room.
(C) Be sure to provide means for the secure installation
of the stove to the floor of the mobile home.
(D) Stove pipe used to connect the stove to the chimney
or flue MUST BE double-wall insulated pipe, or
equivalent, NOT single wall pipe.
(E) A source of external combustion air must be
provided using the optional mobile home installation kit.

2. INSTALLATION OF EXTERNAL AIR DUCT

(A) Position the pedestal on the floor protector where
the stove will be installed.
(B) Mark and cut a 3" diameter hole through the floor
protector and flooring materials for the installation of
the flexible duct.
(C) Attach the flexible duct to the air pipe opening, then
attach the pedestal to the bottom of the stove. (FIGURE
11)
(D) Proceed with the normal freestanding installation.
For further information on safe stove installation, send
for a copy of the NFPA 's publication "USING COAL
AND WOOD STOVES SAFELY," NFPA, No. HS-8-
1974. NFPA 470 Atlantic Avenue, Boston, MA 02210.
RESIDENTIAL CLEARANCE DIMENSIONS
Combustible Wall - Insulated Pipe
Non-Combustible Wall - Insulated Pipe
Combustible Wall - Insulated Pipe/
Heat Shield
Combustible Wall - Double Wall
Air-Cooled Pipe with Heat Shield
The 4N1-XL stove must be connected ONLY to a UL
Listed class "HT" all-fuel burning heating appliance
chimney.
R
S
18"
24"
12"
12"
6"
24"
14"
18"
11