18

Chimney Clearances to Combustibles

WARNING:
Follow the clearances listed below - do not follow the clearances listed in the
chimney instructions
Maintain a 2" clearance from the chimney to combustibles (measured horizontally). See
Figure 22.
Use offsets, if necessary, to maintain clearances
In the area above the fireplace before the chimney penetrates the ceiling (use a firestop), the
chimney must maintain the clearances listed below:
-- 5" to the rear of the chimney
-- 4-1/2" to the front of the chimney
Firestop
Min. 2" clearance to
the sides with offsets
Min. 4-1/2" clearance
to the front.
© Travis Industries
Installation
(for qualified installers only)
Min. Clearance 2" (from this
point upwards)
Min. 5" clearance
to the rear.
4090921
The fireplace enclosure must not be
less than 81" above the base of the
fireplace.
• If the fireplace is raised, the
enclosure height must be raised to
maintain the 81".
• Do not build into this area.
• Do not slope the walls inward.
Figure 22
93508093