conductibility.
2.Tighten 6 screws and make sure there is no gap
between heater DU and bottom of oven cavity.
3.Do not forget to screw the thermal cutout bracket
along with heater Du.
To install thermistor
NOTE:
Before installing thermistor, please fill enough
silicon grease into the installation hole of heater DU
for good conductibility.
4.11. Convection motor and
convection heater
1. Disconnect 2 lead wires from the harness of noise filter (U),
which connecting to both "Negative" and "live" lead of circuit
breaker.(blue and yellow connectors)
2. Disconnect 2 lead wires from circuit breaker harness
connecting to main lead wire harness. (black and green
connectors)
3. Remove 1 screw holding side cover on cavity back plate.
4. Remove 1 screw holding side cover on the side of back
cover, then remove side cover & circuit breaker.
5. Disconnect 2 lead wires from convection heater terminals.
6. Remove 1 screw holding back cover on the lower of back
plate, then remove back cover and back cover C module.
7. Release 3 tabs holding harness on connection outside
cover B.
8. Disconnect 2 lead wires from thermal cutout and convection
motor terminals respectively.