Gas Line Location - Travis Industries 864 ST Installation Manual

Travis industries built-in direct vent fireplace
Hide thumbs Also See for 864 ST:
Table of Contents

Advertisement

Finalizing the Installation

Gas Line Location

Right Side Gas Inlet (preferred)
A 8" flex tube and shutoff valve is
included with the fireplace. The
shutoff valve accepts a 1/2"MPT.
Left Side Gas Inlet
An additional 2" by 3" opening is located the
left side (it is centered 3" above the base of
the fireplace).
5-3/8"
You may remove this cover plate to install the
gas line. The cover plate has a 7/8" diameter
hole (covered with a push plug) in line with the
gas inlet on the gas control valve. By rotating the
plate 180° the hole may be re-located. You may
also secure the plate in a customized location
© Travis Industries
using the self-drilling screws.
4071126
(for qualified installers only)
A 2" by 3" opening is located behind the gas
inlet cover plate (it is centered 3" above the
base of the fireplace).
6-1/4"
10-1/2"
The gas inlet is located 3" above
the base of the fireplace.
You may remove this cover plate to install the gas line. The
cover plate has a 7/8" diameter hole (covered with a push
plug) in line with the gas inlet on the gas control valve. By
rotating the plate 180° the hole may be re-located. You may
also secure the plate in a customized location using the self-
drilling screws.
A 8" flex tube and shutoff valve is
included with the fireplace (you may
wish to use a 24" or 36" flex tube).
The shutoff valve accepts a 1/2" MPT.
15
100-01195_000

Advertisement

Table of Contents
loading