Wiring; Power; Power Terminal (+12V); Ground Terminal (Gnd) - Jensen XA2125 Installation And Operation Manual

Jensen amplifier installation and operation
Table of Contents

Advertisement

XA2125, XA275, XA250

Wiring

Power

Power Terminal (+12V)

Connect directly to the vehicle battery+
terminal with 8 gauge wire (minimum).
Fuse
XA2125
60 AMP
XA275
30 AMP
XA250
25 AMP
Fuse or
Circuit Breaker
Battery
Install as close
Terminal
to the battery
Adapter
as possible

Ground Terminal (GND)

Connect to a good chassis ground. The ground
connection should be to clean, unpainted metal
to provide a good electrical connection.
Sheet Metal
Screw
Drill 1/8" hole
in chassis
sheet metal
6236 XA2CH_E.p65
GND
REM
+ 12V
FUSE
GND
REM
+ 12V
Spade
Connector
8 Gauge
Wire
To Battery+
Terminal
GND
REM
+ 12V
Spade
Connector
8 Gauge
Wire
5
BRIDGE
R
R
L
L

Remote Terminal (REM)

Connect the power antenna/amplifier turn-on
lead from the receiver to the AMPLIFIER
REMOTE terminal.
GND
To Receiver
Power
Antenna Lead

Fuses

Use only blade-type fuses.
Fuse
XA2125
30 AMP x 2
XA275
30 AMP x 1
FUSE
XA250
25 AMP x 1
5/7/01, 2:07 PM
®
REM
+ 12V
Spade
Connector
18 Gauge
Wire
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xa250Xa275