Finalizing Maintenance - A.O. Smith BFC-28 Installation, User And Service Manual

High efficient condensing water heater
Table of Contents

Advertisement

15
15.4.3
15.5 Finalizing
maintenance
90
Performing maintenance
Clean heat exchanger
1. Detach the burner.
2. Clean the combustion chamber of the heat exchanger using a vacuum
cleaner and a soft brush.
3. Detach the chimney flue.
4. Clean the end of the heat exchanger using tap water.
5. Fit the burner.
6. Fit the chimney flue.
Note
Check the pressure differential again after cleaning. If the pressure
differential is too low following cleaning, please contact the supplier of the water
heater.
See Eratta.
1. Fill the water heater (5 "Filling").
2. Start the water heater (9 "Starting the water heater")
3. Check the CO
value (3.11.3 "CO
2
4. Check the switching pressure of the pressure switch. (3.11.4 "Switching
pressure measurement")
5. Erase the message SERVICE REQUIRED. Do this by pressing once on
then once on
adjustment").
2
.
Instruction manual BFC
s

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bfc-30Bfc-80Bfc-100120Bfc-50Bfc-60 ... Show all