Input Type
Network Alarm
Active Camera
PTZ Preset
Auto Lock
Alarm Output
Output Type
Timeout Duration
Apply To
setup screen.
This field is to change the type of alarm trigger.
N.O.
Normal Open contact.
N.C.
Normal Closed contact.
Check box to send out a network alarm to client PC when motion occurs. (requires
PowerCon software and setting up Alarm Server in Network Setup menu)
This field is for associating and alarm trigger with a specific camera. For example
if you had an external motion detector near camera four you would set this option
to "4". The alarm will be associated with this camera for optional full screen
display, event logging, and PTZ preset activation.
Select PTZ Preset from "1" to "255". If the Active Camera is a PTZ speed dome,
the alarm will move the camera to the specified preset position for event recording.
Click "On" to confirm selection, "Off" to cancel selection. When "ON" a sub-menu
is displayed for choosing the desired PTZ preset number.
Check the box and the events will be recorded in the write protected segment of
the Hard Disk. (DVR will lock a period of time when alarm happen, the length of
time will depend on DVR setting)
Selection of relay output as event reaction "NONE" (not active), "1" ~ "4" for the
relay (in 4 channel version is only 1 relay available).
Output action when alarm is triggered.
Timeout
Alarm output lasts for the set time duration.
Permanent
Alarm will remain active until user presses the "Enter" key or
Transparent
Alarm output remains as long as the alarm input is active.
Trans+Timeout Alarm output continues until event ends, then continues for the
Time duration selectable from 1 to 150 seconds.
This button can be used to copy the alarm settings to other cameras. Select which
cameras you wish to copy to.
"Select All" selects all cameras, "Unselect All" deselects all cameras. Click "OK" to
copy the settings or "Cancel" to exit without copying.
resets the alarm remotely.
set time duration.