Wsw14 Auto Ans Facility Setting - Brother MFC8420 Service Manual

All in one printer
Hide thumbs Also See for MFC8420:
Table of Contents

Advertisement

Selector
No.
1
Frequency band selection
(Lower limit)
2
3
Frequency band selection
(Upper limit)
4
5
|
No. of rings in AUTO ANS mode
8
l
Selectors 1 through 4:
These selectors are used to select the frequency band of calling signals for activating the
AUTO ANS facility.
In the French versions, if the user sets the PBX to OFF from the control panel, the setting
made by selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32
Hz. (Even if the setting made by these selectors does not apply, it will be printed on the
configuration list.)
l
Selectors 5 through 8:
These selectors set the number of rings to initiate the AUTO ANS facility.
WSW14 (AUTO ANS facility setting)
Function
Frequency band selection
No. of rings in AUTO ANS mode
A-21
MFC-8420/8820D/8820DN, DCP-8020/8025D/8025DN
Setting and Specifications
No.
1
2
0
0
:
13 Hz
0
1
:
15 Hz
1
0
:
23 Hz
1
1
:
20 Hz
No.
3
4
0
0
:
30 Hz
0
1
:
55 Hz
1
0
:
70 Hz
1
1
: 200 Hz
No.
5
6
7
8
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
SERVICE MANUAL
:
Fixed to once
:
Fixed to 2 times
:
Fixed to 3 times
:
Fixed to 4 times
:
1 to 2 times
:
1 to 3 times
:
1 to 4 times
:
1 to 5 times
:
2 to 3 times
:
2 to 4 times
:
2 to 5 times
:
2 to 6 times
:
1 to 10 times
:
2 to 10 times
:
3 to 5 times
:
4 to 10 times