Peavey MediaMatrix NION Hardware Manual page 64

Programmable digital audio processing node
Hide thumbs Also See for MediaMatrix NION:
Table of Contents

Advertisement

Appendix A - Troubleshooting
The Fault LED tracks the state of the fault relay. (The fault relay signals appear on pins of the
GPIO connector.)
Note: The RED state does not necessarily indicate a problem, but that audio is not actively
being processed and passed. This state occurs normally when the unit is rebooting or has not
yet been configured to run a Project. It also occurs when the unit has encountered a problem
and can no longer process and pass audio.
X-DAB
GREEN
YELLOW OR
GREEN
BLINKING
YELLOW/RED
OR RED
BLINKING
RED
OFF
Note: The XDAB LED is updated only when XDAB is used by the NioNode in the current
Project and the NioNode is up and passing audio.
LAN
GREEN
OFF
CobraNET
GREEN
GREEN
BLINKING
RED
OFF
60
Primary and backup rings are operational.
Running in backup with single cable missing -
all audio present.
Running in backup mode with multiple
cables/nodes missing - some audio gone.
Failure - some or all audio gone. Not running
in backup mode.
XDAB is not in use (in the current Project/Role
for this NioNode).
Ethernet link.
No Ethernet Link.
Ethernet link.
Ethernet link and NioNode is
CobraNet Conductor.
No link or CM-1 missing or
malfunctioning, and NioNode
is configured to use CM-1.
No link or CM-1 missing or
Version 1.6.1.0