HTMA REQUIREMENTS

HYDRAULIC SYSTEM
REQUIREMENTS
FlOW RATE
TOOl OPERATINg PRESSURE
(At the power supply outlet)
SYSTEM RELIEF VALVE SETTING
(At the power supply outlet)
MAXIMUM BACK PRESSURE
(At tool end of the return hose)
Measured at a max. fluid viscosity of:
(At min. operating temperature)
TEMPERATURE
Sufficient heat rejection capacity
to limit max. fluid temperature to:
(At max. expected ambient temperature)
Min. cooling capacity
at a temperature difference of
between ambient and fluid temps
NOTE:
Do not operate the tool at oil temperatures above 140 °F (60 °C). Operation at higher temperatures can cause operator
discomfort at the tool.
FILTER
Min. full-flow filtration
Sized for flow of at least:
(For cold temp. start-up and max. dirt-holding
capacity)
HYDRAULIC FLUID
Petroleum based
(Premium grade, anti-wear, non-conductive)
VISCOSITY
(At min. and max. operating temps)
NOTE:
When choosing hydraulic fluid, the expected oil temperature extremes that will be experienced in service determine
the most suitable temperature viscosity characteristics. Hydraulic fluids with a viscosity index over 140 will meet the
requirements over a wide range of operating temperatures.
*SSU = Saybolt Seconds Universal
10 ► BR37 User Manual
TOOL CATEGORY
TYPE I
TYPE II
4–6 gpm
7–9 gpm
(15–23 lpm)
(26–34 lpm)
2000 psi
2000 psi
(145–155 bar)
(138 bar)
2100–2250 psi
2100–2250 psi
(145–155 bar)
(145–155 bar)
250 psi
250 psi
(17 bar)
(17 bar)
400 ssu*
400 ssu*
(82 centistokes)
(82 centistokes)
140 °F
140 °F
(60 °C)
(60 °C)
3 hp
5 hp
(2.24 kW)
(3.73 kW)
40 °F
40 °F
(22 °C)
(22 °C)
25 microns
25 microns
30 gpm
30 gpm
(114 lpm)
(114 lpm)
100–400 ssu*
100–400 ssu*
TYPE III
11–13 gpm
(42–49 lpm)
2000 psi
(138 bar)
2100–2250 psi
(145–155 bar)
250 psi
(17 bar)
400 ssu*
(82 centistokes)
140 °F
(60 °C)
7 hp
(4.47 kW)
40 °F
(22 °C)
25 microns
30 gpm
(114 lpm)
100–400 ssu*
(20–82 centistokes)
TYPE RR
9–10.5 gpm
(34–40 lpm)
2000 psi
(138 bar)
2200–2300 psi
(145–155 bar)
250 psi
(17 bar)
400 ssu*
(82 centistokes)
140 °F
(60 °C)
6 hp
(5.22 kW)
40 °F
(22 °C)
25 microns
30 gpm
(114 lpm)
100–400 ssu*

Hide quick links: