Hoover 7125-02 User Manual page 8

Ventilating bath fan with light
Table of Contents

Advertisement

Available languages

Available languages

ASSEMBLY INSTRUCTIONS
8.
Mount junction box cover. Replace junction box cover making
sure all wiring connections are fully inside, and are not pinched.
Fig. 8
9.
Attach 4" duct and vent to the outside. Tape duct tube
connection. Fig. 9
Finish ceiling repair if needed.
10. Remove grille (B) from fan body (A). Insert light socket assembly
(D) wiring harness plug (D) through middle hole of grille (B).
Fig. 11
11. Attach wiring harness plug to receptacle inside fan body (A).
Fig. 12
8
Fig. 8
Fig. 9
Fig. 11
Fig. 12
www.homewerksww.com