Assembly Instructions - Existing Construction - Hoover 7125-02 User Manual

Ventilating bath fan with light
Table of Contents

Advertisement

Available languages

Available languages

ASSEMBLY INSTRUCTIONS
INSTALLATION IN EXISTING CONSTRUCTION
Note: Installing the fan body in an existing building requires
an accessible area (attic or crawl space) above the planned
installation location. If you do not have attic space, you will not
be able to install this fan.
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
1.
Existing Fan – remove the existing fan and check to make sure
the opening is large enough to accommodate new fan body.
Use the grille (B) from the new exhaust fan as a template to
mark position of the opening. Fig. 1
2.
Cut out opening for the fan body (A). If hole is too large the
fan globe will not hide it. Fig. 2
Note: Ceiling repair may be required if your existing hole
does not meet the dimensions of the new fan.
3.
Insert the suspension brackets (G) into the fan body (A). Fig. 3
If joist spacing is between 21-1/4 in. and 23-1/2 in., connect
suspension bracket I (F) and suspension bracket II (G) using
short machine screws (BB).
F
Short machine
screws
G
6
Fig. 1
Fig. 2
Fig. 3
www.homewerksww.com

Advertisement

Chapters

Table of Contents
loading

Table of Contents