Start-Up And Shut Down - Beko DRYPOINT RS 1300-6000 HP45 Instructions For Installation And Operation Manual

High pressure compressed air refrigeration dryer
Table of Contents

Advertisement

Start-up
9.3

Start-up and shut down

During short-term shut down (max. two to three days), it is advisable to leave the dryer and the control
panel connected to the supply current circuit. Otherwise, it would be necessary at a restart of the dryer to
wait two hours, until the oil in the compressor has reached the specified operating temperature.
Start-up (see Section 11.1"Control panel")
 Make sure that the condenser is clean (air-cooled).
 Ensure that the cooling-water flow and the temperature are in accordance with the provisions (water-cooled).
 Display DMC24 shows
 Press the
button for at least two seconds to start the dryer: If the compressor was out of operation for a
sufficient period of time, it will start immediately. If this is not the case, the display shows the countdown of the
seconds until the compressar restarts and the
 Wait for several minutes and then check whether or not the dew point temperature which is indicated on the display
of the DMC24 electronics is correct and whether or not the condensate is discharged at regular intervals.
 Switch on the air compressor.
Shut down (see Section 11.1"Control panel")
 Ensure that the dew point temperature indicated on the DMC24 is within the permissible range.
 Shut down the air compressor.
 Switch the dryer off after several minutes by pressing the
display then shows
Dryer remote control ON/OFF
 See instructions in Section 11.18.7
Only use potential-free contacts that are suitable for low voltage. Ensure the sufficient insulation of
potentially dangerous voltage-carrying components.
CAUTION!
Automatic restart / remote control ON/OFF. The unit may start up without any active influence!
The user will be responsible for the installation of proper protections for possible sudden power
restoration to the dryer.
Note!
A dew point between 0°C and +10°C displayed on the control unit is considered to be correct according
to the possible operating conditions (flow rate, air inlet temperature, ambient temperature etc.).
During the operation, the refrigerating compressor runs continuously. The dryer needs to be switched on during the
entire compressed-air usage time, even if the compressed-air compressor works periodically.
Note!
The dryer must not be started up more than six times an hour. Wait at least five minutes prior to
every restart.
The user is responsible for the compliance with these provisions. Irreparable damage can be caused
when starting up the device too often.
22
.
.
LED flashes (max. delay five minutes).
button on the DMC24 for at least two seconds. The
DRYPOINT® RS 1300-6000 HP45