(3) Sensible heat factor

(a) Cooling
1) Model 302
1.05
1.00
0.95
0.90
0.85
0.80
0.75
0.70
0.65
0.60
-15 -13
2) Models 402~602
1.10
1.00
Indoor air
temperature 12˚CW.B
0.90
0.80
0.70
0.60
0.50
-15 -13
Indoor air
temperature 12˚CW.B
Indoor air
temperature 19˚CW.B
-9
-5
-1
3
Ambient air temperature (˚CDB)
Indoor air
temperature 19˚CW.B
-9
-5
-1
3
Ambient air temperature (˚CDB)
Indoor air
temperature 16˚CW.B
7
11
15
19
Indoor air
temperature 16˚CW.B
7
11
15
19
133
-
-
Indoor air
temperature 24˚CW.B
23
27
31
35
Indoor air
temperature 24˚CW.B
23
27
31
35
39
43
39
43