WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

8. Conversion to LP Gas

Check the 'Technical Data' section at the back of the book
that the hob is convertible to the gas you want to use.
A suitably competent person must perform the conversion.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate
n
n
any warranty or liability claims and lead to prosecution.
When servicing or replacing gas-carrying components
n
n
disconnect from the gas supply before starting operation.
Check the appliance is gas sound after completion.
DO NOT use reconditioned or unauthorised gas controls.
n
n
Disconnect from the electricity supply before servicing.
n
n
Before electrical reconnection, check that the appliance is
n
n
electrically safe.

Injectors

Remove the burner caps and heads. Remove the old jets
(Fig. 8.1). Fit the new jets (see 'Technical Data' for the correct
jets). Reassemble in the reverse order.

Tap Adjustment

Removing the Control Panel

Pull off all the control knobs and remove the handrail.
Unscrew the 2 cross-headed screws hidden behind the
handrail end brackets (Fig. 8.2) and remove the 3 fixing
screws underneath the control panel (Fig. 8.3).
The control panel will drop down slightly. It is held at the top
by three holes in the top edge that locate on the tags on the
inner panel (Fig. 8.3). Lift the control panel clear of the tags
and pull forwards, taking care not to damage or strain the
wiring.

Bypass Screw Adjustment

Turn the bypass screw on each control clockwise to the stop
(Fig. 8.4). Refit the control panel.

Stick on Label

Stick the LP gas label over the natural gas part of the
appliance data label.
A
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
Art No 215-0028 - Handrail fascia fixings
ArtNo.270-0032 - 90 Prof+ FX - Removing the control panel
ArtNo.0102-0011 - Screwing
the control valve bypass screw
27
Fig. 8.1
B
C
Fig. 8.2
Fig. 8.3
Fig. 8.4