SV650K7/SK7/AK7/SAK7 ('07-MODEL)

STP SENSOR ADJUSTMENT

If the STP sensor adjustment is necessary, measure the sensor
out put voltage and adjust the STP sensor position as follows:
• Remove the air cleaner box. (#Page 51)
• Disconnect the STVA coupler. (#Page 28)
• Insert the needle pointed probes to the STP sensor lead wire
coupler.
• Turn the ignition switch ON.
• Close the secondary throttle valve by finger, and measure the
STP sensor out put voltage.
$ STP sensor output voltage
ST valve is full closed: Approx. 0.6 V
" 09900-25008: Multi-circuit tester set
09900-25009: Needle pointed probe set
' Tester knob indication: Voltage (()
• If the STP sensor voltage is out of specification, loosen the
STP sensor mounting screw and adjust the STP sensor volt-
age to specification.
• Tighten the STP sensor mounting screw.
" 09930-11950: Torx wrench
& STP sensor mounting screw:
(+ Yellow – - B/Br)
3.5 N·m (0.35 kgf-m, 2.5 lb-ft)