Electrical data (cont)
SUPPLY
38APD
VOLTAGE
UNIT
V-Ph-Hz
SIZE
Min
208/230-3-60
187
380-3-60
342
025
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
027
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
030
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
040
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
050
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
060
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
070
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
080
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
090
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
100
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
115
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
130
460-3-60
414
575-3-60
518
380/415-3-50
342
LEGEND
FLA
— Full Load Amps
ICF
— Maximum Instantaneous Current Flow
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
RLA
— Rated Load Amps
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the
unit terminals is not below or above the listed minimum and maximum limits.
Maximum allowable phase imbalance is: voltage 2%; amps 10%.
2. All units or modules have single point primary power connection. Main power
must be supplied from a field-supplied disconnect.
3. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
90
38APD STANDARD FAN ELECTRICAL DATA
COMPRESSOR
CIRCUIT A
Max
Qty
RLA
LRA
Qty
254
48.1
245
418
23.7
145
506
1
18.6
125
632
14.7
100
440
18.6
118
254
51.3
300
418
26.9
139
506
1
23.1
150
632
19.9
109
440
23.1
140
254
55.8
340
418
34.0
196
506
1
26.9
179
632
23.7
132
440
26.9
174
254
35.8
239
418
23.7
145
506
2
17.9
125
632
14.3
80
440
17.9
118
254
51.3
300
418
26.9
139
506
2
23.1
150
632
19.9
109
440
23.1
140
254
51.3
300
418
26.9
139
506
2
23.1
150
632
19.9
109
440
23.1
140
254
55.8
340
418
34.0
196
506
2
26.9
179
632
23.7
132
440
26.9
174
254
55.8
340
418
34.0
196
506
2
26.9
179
632
23.7
132
440
26.9
174
254
51.3
300
418
26.9
139
506
3
23.1
150
632
19.9
109
440
23.1
140
254
55.8
340
418
34.0
196
506
3
26.9
179
632
23.7
132
440
26.9
174
254
55.8
340
418
34.0
196
506
3
26.9
179
632
23.7
132
440
26.9
140
254
55.8
340
418
34.0
196
506
3
26.9
179
632
23.7
132
440
26.9
174
CONDENSER FAN
CIRCUIT B
Total Qty
RLA
LRA
48.1
245
23.7
145
1
18.6
125
2
14.7
100
18.6
118
51.3
300
26.9
139
1
23.1
150
2
19.9
109
23.1
140
55.8
340
34.0
196
1
26.9
179
2
23.7
132
26.9
174
33.4
225
19.2
140
2
16.7
114
3
13.4
80
16.7
111
51.3
300
26.9
139
2
23.1
150
3
19.9
109
23.1
140
55.8
340
34.0
196
2
26.9
179
4
23.7
132
26.9
174
46.1
245
23.7
145
3
18.6
125
4
14.7
100
18.6
118
55.8
340
34.0
196
3
26.9
179
5
23.7
132
26.9
174
55.8
340
34.0
196
3
26.9
179
6
23.7
132
26.9
174
55.8
340
34.0
196
3
26.9
179
6
23.7
132
26.9
174
73.9
505
38.2
290
3
30.4
225
7
24.6
180
30.4
225
85.3
605
51.9
353
3
41.9
272
8
34.7
240
41.9
272
4. Wiring for main field supply must be rated 75 C. Use copper conductors only.
a. Incoming wire size range for terminal block with MCA up to 175 amps is
14 AWG (American Wire Gage) to 2/0.
b. Incoming wire size range for terminal block with MCA from 175.1 amps
to 420 amps is 2 AWG to 600 kcmil.
c. Incoming wire size range for non-fused disconnect with MCA up to
100 amps is 14 AWG to 1/0.
d. Incoming wire size range for non-fused disconnect with MCA from
100.1 amp to 200 amps is 6 AWG to 350 kcmil.
e. Incoming wire size range for non-fused disconnect with MCA from
200.1 amp to 450 amps is 3/0 to 500 kcmil.
MCA
MOCP
FLA
6.6
121.4
150
3.9
61.1
80
3.3
48.5
60
2.6
38.3
50
3.3
48.5
60
6.6
128.6
175
3.9
68.3
90
3.3
58.6
80
2.6
50.0
60
3.3
58.6
80
6.6
138.8
175
3.9
84.3
110
3.3
67.1
90
2.6
58.5
80
3.3
67.1
90
6.6
167.2
200
3.9
103.5
125
3.3
83.6
100
2.6
66.7
80
3.3
83.6
100
6.6
231.4
250
3.9
119.6
125
3.3
99.1
110
2.6
82.0
100
3.3
99.1
110
6.6
254.6
300
3.9
145.9
175
3.3
119.9
125
2.6
103.5
125
3.3
119.9
125
6.6
296.3
300
3.9
163.2
175
3.3
129.5
150
2.6
107.8
125
3.3
129.5
150
6.6
326.0
350
3.9
198.0
225
3.3
157.7
175
2.6
137.4
150
3.3
157.7
175
6.6
374.9
400
3.9
214.6
225
3.3
176.5
200
2.6
152.3
175
3.3
176.5
200
6.6
388.4
400
3.9
235.9
250
3.3
187.9
200
2.6
163.7
175
3.3
187.9
200
6.6
453.8
500
3.9
253.5
300
3.3
202.6
225
2.6
169.3
175
3.3
202.6
225
6.6
497.4
500
3.9
301.9
350
3.3
243.3
250
2.6
204.7
225
3.3
243.3
250
REC
ICF
FUSE
150
306.3
70
176.5
60
150.2
45
119.9
60
143.2
150
364.5
80
173.7
70
179.7
60
134.1
70
169.7
175
409.0
100
237.8
80
212.5
70
160.9
80
207.5
175
361.4
110
218.9
90
186.2
70
128.8
90
179.2
250
467.3
125
225.0
110
220.2
90
166.1
110
210.2
300
524.8
175
299.4
125
265.3
110
205.9
125
260.3
300
566.5
175
316.7
150
274.9
125
210.2
150
269.9
350
596.2
225
351.5
175
303.1
150
239.8
175
298.1
400
645.1
225
368.1
200
321.9
150
254.7
200
311.9
400
658.6
250
389.4
200
333.3
175
266.1
200
328.3
500
866.4
250
495.7
225
389.6
175
318.5
225
389.6
500
995.8
350
590.0
250
462.9
225
401.3
250
462.9