Options And Accessories - Carrier GEMINI SELECT 38APS025-065 Product Data

Commercial air-cooled condensing units with puron refrigerant (r-410a) 50/60 hz
Hide thumbs Also See for GEMINI SELECT 38APS025-065:
Table of Contents

Advertisement

Options and accessories

Condenser Coil/Low Sound Options
E-Coated MCHX
Low Sound Fan(s)
Compressor Blankets
Vibration isolation Pads
Line Length Options
Long Line Length Check Valve
Ambient/Capacity Control/Interrupt Options
Digital Compressor*
High Short Circuit Current Rating Interrupt
Motormaster V Low Ambient Control
Electrical Options
Dual Point Power
Non-Fused Disconnect
Controls/Communications Options
Navigator™ Display
Remote Enhanced Display
Touch Pilot™ Display
ComfortLink™ Controls with Scrolling Marquee Display Module
EMM
BACnet Translator Control
LON Translator Control
Packaging/Security Options
Bottom Skid
Top Crate, Bag
Security Grilles/Hail Guards
Wind Baffles
LEGEND
E-Coated — Epoxy Coating Applied to Entire Coil Assembly
EMM
— Energy Management Module
LON
— Local Operating Network
MCHX
— Microchannel Heat Exchanger
Factory-installed options
®
Novation
heat exchanger technology microchan-
nel coil (aluminum fin/aluminum tube) condenser is
available for optimum durability. Novation heat exchangers
with microchannel coil technology are offered coated or
uncoated to match coil protection to site conditions. The
Carrier Electronic Catalog (E-Cat) can be used to deter-
mine whether or not corrosion protection is recommended
for particular applications in coastal/marine environments.
Following the input of the requested data, the E-Cat pro-
gram output will advise the appropriate coil to be used.
Other factors described in "Selection Guide: Environmental
Corrosion Protection, Novation Heat Exchanger with Mi-
crochannel Coil Technology" catalog number 04-581042-
01 must also be considered to determine if corrosion pro-
tection is required.
Low sound fans provide a specially designed system of
fan propellers and stacks that reduce sound without reduc-
ing unit performance. The factory-installed fan option is
compatible with the Motormaster
fans are also available as field-installed accessory
Compressor sound blankets reduce unit sound levels
by providing an acoustic blanket on each compressor.
Compressor blankets are also available as field-installed ac-
cessory.
Security grilles/hail guards consist of louvered, sheet
metal panels which securely fasten to the unit and provide
condenser coil protection against hail and physical dam-
age. Security grilles/hail guards are also available as field-
installed accessories.
10
ITEM
®
V option. Low sound
FACTORY-INSTALLED OPTION
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*Digital compressors provide incremental unloading from full capacity
down to a minimum value. Not available on size 065 unit.
NOTES:
1. Std Interrupt - SCCR (short circuit current rating) (5K)
2. High Interrupt - SCCR 460-v and 380/415-v (65K), 208/230-v
(65K), 575-v (25K)
Long line length check valves are required for liquid
line installation on all linear line length applications
of more than 100 ft (30.5 m). For any 025-030 size
dual-circuit unit application where evaporator is located
higher than the condensing unit, check valves are required
for linear line length above 55 ft (16.8 m). The check valve
option prevents charge migration to compressor. Check
valves are also available as field-installed accessories.
Digital compressor control allows incremental unload-
ing for a closer match to building load. Refer to Loading
Sequences tables in Application Data section on page 99.
Digital compressor option not available on unit size 065.
High short circuit current rating interrupt provides a
short circuit current rating protection for the unit up to
65,000 A on 460-v, 380/415-v, and 208/230-v units or
25,000 A on 575-v units.
®
Motormaster
V low-ambient control provides con-
trol of outdoor-fan motor operation to maintain head pres-
sure at low outdoor ambient temperatures down to 20 F
( 29 C) for 50 and 60 Hz units. Only one factory-installed
low ambient temperature kit per unit is required. This
option also requires field-installed wind baffles. The
Motormaster V low-ambient control is also available as a
field-installed accessory.
Dual point power connection option is provided with
terminal blocks for size 115 and 130 units.
Non-fused disconnect includes factory-installed non-
fused disconnect capability for power and control located
at the unit.
ComfortLink™ controls with scrolling marquee
display module is used for accessing condensing unit
FIELD-INSTALLED ACCESSORY
X
X
X
X
X
X
X
X
X
X
X
X
X