4-15. Electrical Service Guide

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
Input Voltage (V)
Input Amperes (A) At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Time-Delay Fuses
Normal Operating Fuses 3
Min Input Conductor Size In AWG 4
Max Recommended Input Conductor Length In Feet
(Meters)
Min Grounding Conductor Size In AWG 4
Reference: 2011 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" . See UL 248.
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amps), and UL class "H" ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.
Notes
380
149
1
2
175
225
1/0
398 (121)
4
Three-Phase, 50/60 Hz
400
415
500
141
136
113
175
150
125
200
200
175
1/0
1/0
441 (134)
474 (145)
490 (149)
6
6
Work like a Pro!
Pros weld and cut
Three-Phase, 60 Hz
460
575
123
98
150
110
175
150
2
1
3
482 (147)
548 (167)
6
6
6
safely. Read the
safety rules at
the beginning
of this manual.
OM-2221 Page 23