115 Volts Ac Receptacle And Circuit Breaker (460 And 575 Volt Input Models); 230 Volts Ac Receptacle And Circuit Breakers (400 Volt Input Models) - Miller Summit Arc 1000 Owner's Manual

Ce and non-ce
Hide thumbs Also See for Summit Arc 1000:
Table of Contents

Advertisement

4-13. 115 Volts AC Receptacle And Circuit Breaker (460 And 575 Volt Input Models)

4-14. 230 Volts AC Receptacle And Circuit Breakers (400 Volt Input Models)

OM-2221 Page 22
1
2
1
2
3
1
115 V 12 A AC Receptacle
Power is shared between the du-
plex receptacle and the 115 volt
output connections at terminal strip
TE3 and the Remote 14 receptacle
(see Section 4-10).
2
Circuit Breaker CB1
CB1 protects 115 volts AC recep-
tacle and 115 volts AC portion of
terminal strip TE3 and Remote 14
receptacle from overload.
Ref. 175 086 / Ref. 801 882-B
1
230 V 16 A AC Receptacle
2
Circuit Breaker CB1
CB1 protects the 115 volts AC por-
tion of terminal strip TE3 and Re-
mote 14 receptacle from overload.
3
Circuit Breaker CB4
CB4 protects the 230 volts AC re-
ceptacle from overload.
Ref. 175 086 / Ref. 801 882-B