Section 3 − Installation; Important Information Regarding Ce Products (Sold Within The Eu); Serial Number And Rating Label Location; Specifications - Miller Summit Arc 1000 Owner's Manual

Ce and non-ce
Hide thumbs Also See for Summit Arc 1000:
Table of Contents

Advertisement

4-1. Important Information Regarding CE Products (Sold Within The EU)

A. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner's Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
IEC/TS 61000−3−4 may be used to guide the parties concerned by the installation of arc welding equipment with an input current above 75 Amps
in a low-voltage network.

4-2. Serial Number And Rating Label Location

The rating information for the power source is located on the front or the rear of the machine. Use the rating labels to determine input power require-
ments and/or rated output. The serial number is located on the front of the machine, for future reference, write serial number in space provided on
back cover of this manual.

4-3. Specifications

Voltage
AC or DC
Range in
Rated Output
CV Mode
1000 A at 44 V,
100% Duty Cycle;
25−44 V
1250 A at 44 V,
60% Duty Cycle
*While idling
** This equipment is designed for indoor use and is not intended to be used or stored outside.
OM-2221 Page 12
SECTION 4 − INSTALLATION
Amperage
Max
Range in
Open-Circuit
CC Mode
Voltage
250−1250 A
71 V
RMS Amps Input at Rated Load Output,
3-Phase at NEMA Load
Voltages and Class I Rating
380/400/415 V
460 V
IP
(50/60 Hz)
(60 Hz)
Rating
143
124
21S**
(3*)
(3*)
ce-emf 1 2010-10
ce-emc 5 2010-10
500 V
575 V
(50/60 Hz)
(60 Hz)
KVA
114
100
98
(3*)
(3*)
(2.37*)
KW
53
(0.95*)

Advertisement

Table of Contents
loading