To move the spotlight, move the joystick gently in the desired direction. The light can be
moved both vertically and horizontally at the same time.
Use the toggle switch to activate the spotlight beam (or the floodlight beam for model
503-1). The 2 spotlights can be moved with the beam switched off.
Precautions
DO NOT look directly into the spotlight or floodlight while it is operating.
DO NOT cover the light with a fabric cover or any other flammable material. Accidental
activation may result in a fire hazard.
DO turn the spotlight toward the control station when not in use. If the spotlight is
accidentally activated during daylight, the operator will be more likely to notice and turn
the spotlight off before draining a battery.
503-1 Spot/Floodlight Wiring Diagram
Foam Gasket
10-12 ga. (5mm)
crimp Connector
Black
12 volts DC
1.
Connect the wires from the spotlight
to SAME wire colors of provided cable
Male Plugs on
this end of cable
Red
10 Amp Fuse
12 volts DC
(included)

Operation

Red
12 volts DC
10 Amp Fuse
(or circuit breaker)
2.
Connect the control cable wires to
SAME wire colors of provided cable
Black
12 volts DC
5