Specification - Panasonic CS-E12JKKW-1 Service Manual

Air conditioner
Hide thumbs Also See for CS-E12JKKW-1:
Table of Contents

Advertisement

2. Specification

Model
Performance Test Condition
Power Supply
Capacity
Running Current
Input Power
EER
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Capacity
Running Current
Input Power
COP
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Max Current (A) / Max Input Power (W)
Starting Current (A)
Min Circuit Ampacity
Max. Current Protection
Compressor
Type
Material
Motor Type
Input Power
Output Power
Speed
Outdoor
Phase, Hz
BTU/h
W/W
Btu/hW
dB-A (H / L / QLo)
Power Level dB
dB-A (H / L / QLo)
Power Level dB
BTU/h
W/W
Btu/hW
dB-A (H / L / QLo)
Power Level dB
dB-A (H / L / QLo)
Power Level dB
SEER / HSPF
Type
Motor Type
Output Power
QLo
Lo
Me
Hi
SHi
Indoor
V
Min.
kW
1.20
4100
A
-
W
250
4.80
16.40
%
-
43 / 28 / 20
59 / - / -
46 / - / -
61 / - / -
kW
1.20
4100
A
-
W
250
4.80
16.40
%
-
44 / 35 / 32
60 / - / -
47 / - / -
62 / - / -
W
W
W
rpm
rpm
rpm
rpm
rpm
5
CS-E12JKKW-1
CU-E12JKK-1
ARI
Single, 60
208
Mid.
Max.
Min.
3.48
3.85
1.20
11900
13100
4100
4.8
-
-
950
1.15k
250
3.66
3.35
4.80
12.55
11.40
16.40
95
-
-
4.41
6.20
1.20
15000
21200
4100
6.3
-
-
1.25k
1.90k
250
3.53
3.26
4.80
12.00
11.15
16.40
95
-
-
8.4 / 1.92k
6.3
15.0
15.0
17.50 / 9.50
Hermetic Motor
Brushless (6 poles)
700
Cross-flow fan
ASG20K1
Transistor (8 poles)
47.0
30
Cooling : 630
Heating : 970
Cooling : 790
Heating : 1070
Cooling : 1030
Heating : 1250
Cooling : 1270
Heating : 1430
Cooling : 1400
Heating : 1500
230
Mid.
Max.
3.48
3.85
11900
13100
4.3
-
950
1.15k
3.66
3.35
12.55
11.40
96
-
43 / 28 / 20
59 / - / -
48 / - / -
63 / - / -
4.41
6.20
15000
21200
5.6
-
1.25k
1.90k
3.53
3.26
12.00
11.15
97
-
44 / 35 / 32
60 / - / -
49 / - / -
64 / - / -

Hide quick links: