Error Code
Description
00B8
Remote side disconnect after our side sending DCS signal in V.34.
00BA
Cannot received correct signal after our side sending DTC signal in V.34.
00BB
Every time our side received DIS signal after sending DTC in V.34.
00BC
Modem can't ready within 10 second after entering primary channel in V.34.
00BD
Can't detect correct V.21 or JM signal after detected FSK frequency.
00BE
Remote side no document to be polled after V.8 handshaking.
00BF
Capability no match after V.8 handshaking
00C1
At phase-D, transmitting units out EOP 3 times consecutively, but receive no answer from receiving unit.
00C2
Remote side disconnect after sending out V.8 CM signal.
00C4
After sending MPS signal, the received is not one of MCF, RTN, PIP, PIN, RTP, DCN.
00C5
Received DCN signal after sending MPS signal.
00C9
At phase D, sending MPS 3 times consecutively, but no answer from receiveing unit.
00CA
After sending EOP signal, the received is not one of MCF, RTN, PIP, PIN, PRI-EOP, DCN, RTP.
00CB
After sending EOP signal, the received is DCN signal.
00CF
Received incorrect signal after sending DTC signal for V.34 polling.
00D0
Received ERR signal after sending EOR_NULL.
00D1
Received incorrect response after sending PPS_EOP signal
00D2
Received DCN after sending PPS_EOP signal
00D3
Received DCN after sending PPS_NULL signal
00D8
Can't detect correct phase 3 signal for poling.
00D9
Can't detect correct phase 3 signal after detect silence after phase 2.
00DA
Can't detect phase 4 signal within 30 sec.
00DB
Can't received any T.30 signal within 30 sec within phase 4.
00DC
Received T.30 signal in phase 4 other than DCS, DIS or DTC
00DE
Remote side no SUB capability.
00E0
At phase-D, transmitting units out PPS_NULL 3 times consecutively but receive not answer.
00E1
Received incorrect response after sending PPS_NULL.
00E2
Can't receive any response in RR response procedure after sending PPS_NULL.
00E4
At phase D, transmitting units out PPS_MPS 3 times consecutivery but receive no answer.
00E5
Received incorrect response after sending PPS_MPS signal
00E6
Can't receive any response in RR response procedure after sending PPS_MPS.
00E7
Reseived DCN after sending PPS_MPS.
00E8
At phase-D, transmitting units out PPS_EOP 3 times consecutively but receive no answer.
00E9
Receive PIN signal after sent last page data.
00EA
Can't receive any response in RR response procedure after sending PPS_EOP.
00EE
At phase-D, transmitting units out EOR_NULL 3 times consecutively but receive no answer.
00EF
Received incorrect response after sending EOR_NULL.
00F0
Can't receive any response in RR response procedure after sending EOR_NULL.
00F1
At phasa-D, transmitting units out EOR_MPS 3 times consecutively but receive no answer.
00F2
Received incorrect response after sending EOR_MPS.
00F3
Received ERR signal after sending EOR_MPS.
00F4
Can't receive any response in RR response procedure after sending EOR_MPS.
00F5
At phasa-D, transmitting units out EOR_EOP 3 times consecutively but receive no answer.
00F6
Received incorrect response after sending EOR_EOP
00F7
After Received ERR, our side can't received response after sending EOR_EOP command.
00FC
Can't receive any response after sending CTC.
00FD
Can't speed down to lower speed.
00FE
Memory full for transmission
00FF
REDAIL ALL FAIL