NOTE: Make sure that the power supply cord is disconnected when changing the position of DIP Switch is selected.
The differential switch on the main circuit board controls does not change the heat exchanger water temper-
ature. The switch can be set at a delta (on/off) of 3.6˚F (2˚C), 18˚F(10˚C), or 36˚F (20˚C). A higher delta reduces
burner short cycling.
NOTE: The position of DIP Switch is set to 18˚F differential from factory.
1.
Select the position Differential Switch by the DIP Switch (SW1).
2.
Select the differential range by the DIP Switch, No.2 or No.3.
3.
Make sure that the DIP Switch No.1 is "ON" position.
DIFF
No.
3
2
1
(AVAILABLE FROM A PLUMBING SUPPLY COMPANY)
This water heater is equipped with a power terminal for a circulation pump. You can operate the circulation
pump in conjunction with the power switch of the water heater by connecting the pump to the "K" terminal
of the circuit board.
When the power switch is "ON", the power terminal for the circulation pump "K" constantly outputs
AC120V. Any circulation pump that operates in AC120V and consumes 300W or less can be connected to the
power terminal "K". Use the attached lead wire for circulation pump for wiring according to the instruction
of diagram below.
Remove the open-terminal connected to the "K" terminal.
Connect to the circulation pump using the attached couplers (Red).
See the wiring diagram below for wiring to the circuit board.
Connect the lead wire for circulation pump to the "K" terminal of the circuit board.
How to use the coupler
Make
3/16 in.
(4-5mm)
space.
11

DIFFERENTIAL SWITCH AND DIP SWITCH

3.6˚F (2˚C)
18˚F (10˚C)
OFF
OFF
OFF
ON
ON
WIRING FOR A CIRCULATION PUMP
Lead wire for
circulation pump
Stopper
Power lead wire
of the external
circulation pump
SW1
3
DIP Switch
2
1
36˚F (20˚C)
ON
ON
(K)
Main Circuit Board
Main Circuit Board
SW1
Circulation pump
(available on the market)