Connectors

Connector
CAT 6 jack (black), qty. 10
CAT 6 jack (red), qty. 10
CAT 6 jack (blue), qty. 10
CAT 6 jack (orange), qty. 10
CAT 6 jack (gray), qty. 10
CAT 6 jack (white), qty. 10
CAT 6 jack (ivory), qty. 10

Mounting

CAUTION: Installation and service must be performed by authorized personnel only.
The 1U high, half rack width MTP DA can be set on a table, mounted on a rack shelf,
mounted to a rack without a shelf, or mounted under a desk or tabletop.
NOTE:

UL Guidelines

The following Underwriters Laboratories (UL) requirements pertain to the installation of the
DA into or onto a rack.
1.
2.
3.
4.
5.

Tabletop Use

Four self-adhesive rubber feet are included with the DA. For tabletop use, attach one foot to
each corner of the bottom side of the unit and place the unit in the desired location.
For rack or furniture mount installation, see the installation card that comes in
the kit.
Elevated operating ambient — If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consider installing the equipment in an environment compatible
with the +122 °F (+50 °C) maximum ambient temperature (TMA) specified by Extron.
Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to supply connections (such
as the use of power strips) other than direct connections to the branch circuit.
Part Number
100-476-01
100-477-01
100-478-01
100-479-01
100-480-01
100-481-01
100-482-01
MTP DA4 and MTP DA8 • Reference Information