Changing Components - Potterton Performa System 12 HE Installation & Service Instructions Manual

Wall mounted powered flue condensing boiler gas fired central heating unit
Hide thumbs Also See for Performa System 12 HE:
Table of Contents

Advertisement

Pressure
Switch
Fig. 41
Pressure
Switch Wires
Fan Wires
Sensing
Tubes
Ease Fan Spigot Outlet
Pipe Clamps Inwards
28 model
Fan Spigot Outlet Pipe
Baffle
Spring Clip
Fig. 43
32
Sensing
Tubes
Fan
Fig. 42
12,18,24
model
Tab
Spring Washer
Securing Screw

12.0 CHANGING COMPONENTS

IMPORTANT: When changing components
ensure that both the gas and electrical supplies to
the boiler are isolated before any work is started.
When the new component has been fitted turn the
selector switch fully anticlockwise against the
spring pressure to the 'Reset' position and hold for
2 seconds to reset the boiler before
recommissioning.
See Section 11.1 "Annual Servicing" for removal of
case panel, door etc.
12.1
1. Note the positions of the sensing tube(s) (28 HE
has two - one tube on 12/18/24 HE) on the fan
spigot and three wires on the fan motor and remove
them.
2. Slacken the screws on the fan spigot outlet pipe
clamps. Ease the clamps inwards over the pipe (28
HE). On 12/18/24 HE models undo the securing
screw at the left hand end of the pipe and the clamp
at the right.
3. Draw the outlet pipe away from the boiler.
4. Remove the four screws securing the combustion
box door and remove the door.
5. Ease the front edge of the left hand baffle
upwards, disengaging the spring clip. Disengage the
tabs on the baffle from the slots in the fan hood.
6. Undo the screws securing the fan hood to the
appliance back panel, and draw the fan and hood
assembly forwards.
7. Remove the screws and spring washers securing
the fan to the hood.
8. Fit the new fan to the hood using the screws and
spring washers previously removed.
9. Reassemble in reverse order of dismantling.
Fan
12.2
1. Remove the fan as described in section 12.1.
Fan Hood
2. Note the positions of the two sensing tubes and
three wires and remove them.
3. Remove the two screws holding the pressure
switch to the bracket on the combustion box top
panel.
4. Fit the new pressure switch and reassemble all
components in reverse order of dismantling.
Fan (Figs. 42 & 43)
Pressure Switch (Fig. 41)
Publication No. 5111817

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Performa system 24 hePerforma system 28 he

Table of Contents