GENERAL CHARACTERISTICS

1.9.- CORRECTION FACTORS

AIR FLOW
The data in the capacity tables have been calculated for nominal airfl ow rate; with maximum/minimum airfl ow rates use these cor-
rection factors :
AWC
AIR FLOW RATE
AWH
Maximum
002
Nominal
Minimum
Maximum
003
Nominal
Minimum
Maximum
007
Nominal
Minimum
Maximum
008
Nominal
Minimum
Maximum
010
Nominal
Minimum
Maximum
012
Nominal
Minimum
Maximum
015
Nominal
Minimum
Maximum
018
Nominal
Minimum
Maximum
020
Nominal
Minimum
AIR INLET
COOLING MODE AWC/AWH.
The data in the capacity tables has been calculated for air inlet
temperature: 27ºC DB and 19ºC WB. For another conditions
use these correction factors.
Air inlet temperature
Air inlet temperature
(D.B.)
(W.B.)
21
24
27
29
32
AQUALEAN - AWC/AWH - MIL118E-1407 / 10-2013
Total capacity
kW
1,02
485
1,00
440
0,91
285
1,04
550
1,00
515
0,94
335
1,02
1430
1,00
1250
0,96
1010
1,01
1620
1,00
1500
0,96
1250
1,02
2100
1,00
1900
0,96
1550
1,02
2200
1,00
2000
0,96
1620
1,01
2610
1,00
2450
0,94
1850
1,01
3100
1,00
2800
0,92
2060
1,01
3500
1,00
3100
0,94
2450
TC (kW)
SC (kW)
15
Power input (kW)
TC (kW)
SC (kW)
17
Power input (kW)
TC (kW)
SC (kW)
19
Power input (kW)
TC (kW)
SC (kW)
21
Power input (kW)
TC (kW)
SC (kW)
23
Power input (kW)
COOLING MODE
Sensible capacity
EER
kW
1,04
1,00
1,00
1,00
0,84
0,97
1,10
1,01
1,00
1,00
0,89
0,99
1,06
1,02
1,00
1,00
0,92
0,97
1,03
1,01
1,00
1,00
0,93
0,98
1,04
1,03
1,00
1,00
0,92
0,98
1,03
1,03
1,00
1,00
0,92
0,98
1,03
1,01
1,00
1,00
0,89
0,97
1,03
1,01
1,00
1,00
0,87
0,97
1,03
1,02
1,00
1,00
0,89
0,98
HEATING MODE AWH
The data in the capacity tables has been calculated for air
inlet temperature: 20ºC DB. For another conditions use these
correction factors.
Air inlet temperature (D.B.)
0,88
15
0,89
0,99
17
0,94
0,94
20
1,00
1,00
22
1,00
1,00
24
1,07
0,99
1,00
TC : Total capacity
1,13
SC : Sensible capacity
1,04
D.B. : Dry bulb
1,01
W.B. : Wet bulb
HEATING MODE
Total capacity
Total absorbed power
kW
kW
1,01
0,98
1,00
1,00
0,94
1,11
1,03
0,95
1,00
1,00
0,95
1,08
1,02
0,96
1,00
1,00
0,99
1,08
1,01
0,98
1,00
1,00
0,98
1,06
1,01
0,98
1,00
1,00
0,97
1,07
1,01
0,98
1,00
1,00
0,97
1,09
1,01
0,98
1,00
1,00
0,96
1,12
1,01
0,98
1,00
1,00
0,95
1,12
1,01
0,98
1,00
1,00
0,96
1,12
TC (kW)
Power input (kW)
TC (kW)
Power input (kW)
TC (kW)
Power input (kW)
TC (kW)
Power input (kW)
TC (kW)
Power input (kW)
1,03
0,91
1,02
0,95
1,00
1,00
0,99
1,04
0,98
1,08
• 15 •