Devicenet Baud Rate (Pr. 346) - Mitsubishi Electric FR-A7ND E kit Instruction Manual

Plug-in option
Hide thumbs Also See for FR-A7ND E kit:
Table of Contents

Advertisement

4.2.2

DeviceNet baud rate (Pr. 346)

Parameter
Number
346
DeviceNet baud rate
Set baud rate etc. to start DeviceNet communication.
Bit15
Bit14
Bit13
Bit12
Baud Rate Key
Bit
Item
0, 1
Baud Rate (BR)
Output
2 to 6
Assembly (OA)
Input Assembly
7 to 11
(IA)
12 to 15 Baud Rate Key
Name
Bit11
Bit10
Bit9
Bit8
Input Assembly (IA)
Initial
Setting Range
Value
0, 3
0
1
2
0
1
1
6
Other than the above Output Instance 21 (0x15)
0
1
1
6
Other than the above Input Instance 71 (0x47)
0
0
Minimum Setting
Setting Range
Increments
0 to 4095
Bit7
Bit6
Bit5
Bit4
Output Assembly (OA)
Definition
125kbps
250kbps
500kbps
Output Instance 20 (0x14)
Output Instance 21 (0x15)
Output Instance 126 (0x7E)
Input Instance 70 (0x46)
Input Instance 71 (0x47)
Input Instance 176 (0xB0)
Set "0" always. When a value other than "0" is set, the inverter
operates as when "132" (initial value) is set in Pr. 346.
INVERTER SETTING
Initial
Value
1
132
Bit3
Bit2
Bit1
Baud Rate
(BR)
This value can be set with DeviceNet
Object Class 0x03 Instance 1
Attribute 2. (Refer to page 50)
· Set the same value for input
assembly and output assembly.
· The value can be set with Control
Supervisor Class 0x29 Instance 1
Attribute 140, 141. (Refer to page
69)
Bit0
4
23