Devicenet Baud Rate (Pr. 346) - Mitsubishi Electric FR-A7ND Instruction Manual

Inverter plug-in option devicenet communication function 700 series
Hide thumbs Also See for FR-A7ND:
Table of Contents

Advertisement

INVERTER SETTING
4.2.2

DeviceNet baud rate (Pr. 346)

Parameter
Number
346
DeviceNet baud rate
Set baud rate etc. to start DeviceNet communication.
15
14
13
12
Baud Rate Key
Bit
Item
0, 1
Baud Rate (BR)
Output Assembly
2 to 6
(OA)
Input Assembly
7 to 11
(IA)
12 to
Baud Rate Key
15
16
Name
11
10
9
8
7
Input Assembly
Initial
Setting Range
Value
0, 3
0
1
2
0
1
1
6
Other than the above Output Instance 21 (0x15)
0
1
1
6
Other than the above Input Instance 71 (0x47)
0
0
Minimum Setting
Setting Range
Increments
0 to 4095
6
5
4
3
2
Output Assembly
125kbps
250kbps
500kbps
Output Instance 20 (0x14)
Output Instance 21 (0x15)
Output Instance 126 (0x7E)
Input Instance 70 (0x46)
Input Instance 71 (0x47)
Input Instance 176 (0xB0)
Set "0" always. When a value other than "0"is set, the inverter
operates as when "132" (initial value) is set in Pr. 346.
Initial
Value
1
132
1
0
Baud Rate
Definition
This value can be set with DeviceNet
Object Class 0x03 Instance 1
Attribute 2. (Refer to page 39)
· Set the same value for input
assembly and output assembly.
· The value can be set with Control
Supervisor Class 0x29 Instance 1
Attribute 140, 141. (Refer to page
57)