2.2

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
Altitude
Maximum Input
Maximum Output
Effi ciency
Minimum Inlet Gas Supply Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
* When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Provide adequate accessibility clearance for servicing and operating the appliance.
Never obstruct the front opening of the appliance.
2.3

RATING PLATE INFORMATION

DIRECT VENT VENTED GAS FIREPLACE APPROVED FOR BEDROOM, BATHROOM & BEDSITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED
MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
CAUTION: FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED
BY THE MANUFACTURER WITH THE APPLIANCE.
THIS VENTED GAS FIREPLACE IS NOT FOR USE
WITH AIR FILTERS.
ELECTRICAL RATING: BLOWER KIT GS66, 115V
0.5AMP 60HZ THE APPLIANCE MUST BE VENTED
USING THE APPROPRIATE WOLF STEEL VENT KITS.
SEE OWNERS INSTALLATION MANUAL FOR VENTING
SPECIFICS. MINIMUM AND MAXIMUM VERTICAL
VENT LENGTHS ARE 3 FEET AND 35FEET
RESPECTIVELY.
TOP, SIDES & BACK: PER STAND OFF SPACERS
FOR FRAMING MATERIALS. FOR FINISHING
MATERIALS SEE OWNERS MANUAL.
* MAXIMUM HORIZONTAL EXTENSION 2". SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
RATING PLATE LOCATION: The rating label is located behind the control panel and is chained to the
appliance. DO NOT REMOVE.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
RATES AND EFFICIENCIES
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: ANSI Z21.50b-2009 CSA 2.22b-2009 VENTED GAS FIREPLACE / FOYER AU GAZ AVEC EVACUATION.
9700539 (WSL)
4001658 (NAC)
NATURAL GAS MODEL
COLONNE D'EAU(GN)
GD19N
CDV19N
COLONNE D'EAU (GN)
0-4500ft
11,500 BTU/h
8,000 BTU/h
COLONNE D'EAU (GN)
NOT FOR USE WITH SOLID FUEL
MINIMUM AND MAXIMUM HORIZONTAL VENT
LENGTHS ARE 8 INCHES AND 20 FEET
RESPECTIVELY. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
CE TO COMBUSTIBLE MATERIAL
TOP
0"
MANTEL
MANTEL
FLOOR
0"
RECESSED DEPTH 13
RECESSED DEPTH 13"
SIDES
0"
VENT
VENT
BACK
K
0"
0"
NUAL FOR GRE
NATURAL GAS
0 - 4,500*
11,500
8,600
75%
4.5" Water Column
7" Water Column
3.5" Water Column
FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS UNE
CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS
UNE MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA
Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX
SERIE DE MAISONS M
ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
DE LA NORME DE SECURITE ET
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE
FR, SECTION 3280. DANS LE
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES
4001657
4001657 (NGZ)
4001659 (W
4001659 (WUSA)
PROPANE MODEL
PROPAN
GD19P
GD19
ALTITUDE / ELEVATION
E / ELEVATION
0-4500ft
0-450
INPUT / ALIMENTATION
ALIMENTATION
11,000 BTU/h
REDUCED INPUT /
EDUCED INPUT /
ALIMENTATION REDUITE
LIMENTATION REDUITE
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL
UN COMBUS
ATTENTION: UTIL
ATTENTION: UTILISER AVEC LES PORTES VITREES
ET
HOMOLOGUEE
HOMOLOGUEES SEULEMENT AVEC CETTE
TALLATION AN
UNITE.
UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL
VERTIS
TER SERVICING
AUCU
AUCUN MATERIAU DEVANT ENTRER EN CONTACT
AV
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST
FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE
UTILISÉ CONJOINTEMENT AVEC DES FILTRES À AIR.
2"*
2"*
CLASS:
SOUFFLERIE GS66,
115V 0.5AMP 60HZ
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
1"
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 35 PIEDS RESPECTIVEMENT.
DESSUS, COTES & ARRIERE: SELON LES ESPACEURS DE DEGAGEMENT POUR LES MATERIAUX D'OSSATURE
SELON LE MANUEL DE PROPRIETAIRE POUR LES MATERIAUX DE FINITION.
* L'EXTENSION HORIZONTAL MAXIMALE 2". REFERER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS
PLUS GRANDES.
SERIAL NUMBER / NO. DESERIE
PROPANE GAS
0 - 4,500*
11,000
8,250
75%
11" Water Column
13" Water Column
10" Water Column
R
S À ÉVA
R, UNE SA
BILE SI SON INSTA
, SE REFERER A LA NOR
ENDIE POUR LES I
SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
CDV19P
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 8 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
DESSUS
0"
MANTEAU
PLANCHER 0"
PROFONDEUR DE L'ENCLAVE 13"
COTES
0"
ÉVENT
ARRIÉRE
0"
GD19
7
2"*
1"
W385-0374 / E